Daikin FTXS30LVJU Service Manual page 205

Inverter pair ftxs-l series fdxs-l series
Hide thumbs Also See for FTXS30LVJU:
Table of Contents

Advertisement

Indoor Unit: FTXS15/18/24LVJU
Step
4
Release the harness
from the hooks.
5
Remove the screw of
the electrical box.
6
Lift up the electrical box
from the bottom frame
and remove it.
195
Procedure
(R16280)
Electrical box
3
1 2
(R16281)
 Fit the back hook of the
electrical box to the bottom
frame when reassembling.
(R16282)
SiUS091133
Points
Bottom frame
Hook
(R9647)
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents