SiUS091133
2.4
Removal of PCBs
Procedure
Step
1. Remove the signal
receiver PCB.
1
Unfasten the hooks of
the shield plate.
2
Open the shield plate.
3
Remove the shield
plate.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Indoor Unit: FTXS15/18/24LVJU
Points
Preparation
Remove the electrical box
according to the "Removal of
Electrical Box."
Shield
plate
(R9506)
The shield plate has 2 hooks at
the lower part also.
(R16283)
(R16284)
Hook
(R16498)
196