Service Manual
Checklist D Procedures
7
Push the filter element down to be sure the
o-ring on the element is fully seated into the
housing.
8
Rotate the filter element clockwise to lock it in
place.
9
Install the filter housing cap.
10 Clean up any oil that may have spilled during
the replacement procedure.
11 Use a permanent ink marker to write the date
and number of hours from the hour meter on
the oil filter housing.
12 Turn the key switch to ground controls and pull
out the red Emergency Stop button to the on
position.
13 Move and hold the function enable toggle
switch to either side and move and hold the
primary boom toggle switch in the up direction.
14 Inspect the filter housing and related
components to be sure that there are no leaks.