Genie Z-34/22 Service Manual page 123

Bi-energy power
Hide thumbs Also See for Z-34/22:
Table of Contents

Advertisement

Service Manual
Fault Codes
Fault Codes
Note: Additional troubleshooting of the fault codes
may by accomplished by using the hand-held
pendant motor controller programmer (Genie part
number 56303).
For authorized service personnel only:
Note: When using the hand-held pendant motor
controller programmer, the M1 MAX SPEED needs
to be set to 33. If needed, adjust the M1 MAX
SPEED higher or lower to achieve the maximum
raised drive speed of 0.6 mph / 1Km/h or 40 feet /
45 seconds / 12.2 meters / 45 seconds.
Tip-over hazard. When
adjusting the raised drive speed
settings, the maximum raised
drive speed must not exceed
0.6 mph / 1Km/h or
40 feet/45 seconds /
12.2 meters / 45 seconds. If the
machine is allowed to drive
faster than specification, the
machine could become unstable
and will tip over.
The controller status indicator light will flash a fault
code to aid in troubleshooting. This indicator light
is located on the front of the gound control box.
Fault codes are two digits. The controller status
indicator light will blink the first digit of a two digit
code, pause for 1 second, and then blink the
second digit. There will be a 2 second pause
between codes.
For example: the indicator light blinks
4 consecutive times, pauses for 1 second, and
then blinks 1 time. That would indicate Fault Code
41.
110
Z-34/22 Bi-Energy
April 2016
Part No. 139234