12 Locate the red wire that leads from the voltage
regulator to the positive rectifier assembly.
13 Remove the screw that attaches the red wire
to the positive rectifier assembly.
14 Remove the #4 nut that attaches the black
wire to the voltage regulator.
15 Remove the voltage regulator mounting
screws.
16 Remove the voltage regulator while carefully
guiding the red and black wires from
underneath the bottom support of the positive
and negative rectifier assembly.
17 Install the new voltage regulator by following
the previous steps in reverse order.
18 Apply Loctite® removable thread sealant onto
the voltage regulator mounting fasteners and
torque to specification. Refer to Specifications,
Machine Torque Specifications.
19 Torque all other fasteners to specification.
Refer to Specifications, Machine Torque
Specifications.
20 Install the plastic cover onto the generator
then install the generator onto the machine.
21 Adjust the generator belts. Refer to repair
procedure, How to Adjust the Generator Belts.
22 Adjust the voltage regulator. See How to
Adjust the Voltage Regulator.
Component damage hazard.
The voltage regulator and/or
generator may become
damaged if the voltage
regulator is not properly
adjusted after replacement