V
in
Internal Pull-up
Resistor
Off (default)*
Z
= 100 kΩ
in
Protection
circuitry
* Configurable on the ACEmanager I/O tab
Figure 2-10: Digital Input / Pulse Counter
Table 2-4: Pulse Counter
Pull-up
State
Off
Low
High
2.7

Digital Input

Digital input is available on Pin 4 on the power connector and on Pins 2, 3, 6, and
7 on the auxiliary I/O connector.
You can connect any of these pins to a digital input to detect the state of a switch
such as a vehicle ignition, or to monitor an external device such as a motion
detector, a remote solar panel, or a remote camera. Digital input can also be used
with the standby timer.
22
Minimum
Typical
Pin 4 on the power connector, or
Pin 2, 3, 6, or 7 on the auxiliary
I/O connector
Digital Pulse Generator
≤ 1.0 V
V
Low
≥ 2.7 V
V
High
Maximum
Units
1.0
V
Vin
V