CAME Z 24 Series ZL170N Installation Manual

Control panel for 24v gearmotors

Advertisement

Quick Links

CONTROL PANEL
3 1 9 U34 E N
FOR 24V GEARMOTORS
INSTALLATION MANUAL
ZL170N
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME Z 24 Series ZL170N

  • Page 1 CONTROL PANEL 3 1 9 U34 E N FOR 24V GEARMOTORS INSTALLATION MANUAL ZL170N English...
  • Page 2: Legend Of Symbols

    The overall power load of the connected motor must not exceed 180 W. 3 Reference standards Came Cancelli Automatici employs an ISO 9001:2000 certified quality management system and an ISO 14001 environmental management system. Came entirely engineers and manufactures in Italy.
  • Page 3 4.1 Dimensions, centre distances and anchoring holes (mm) 4.2 Main components M N R ADT x ZL170 WHITE BROWN BLUE BLACK 1. Transformer 6. Code memorising button 13. 3.15A-F line fuse 14. Radio frequency card socket 2. Amperometric sensitity during travel 7.
  • Page 4: Installation

    5 Installation Warning! Before acting on the eqipment, cut off the main power supply and disconnect the emergency batteries (if present). Installation must be carried by skilled, qualified technicians in accordance with current regualtions. 5.1 Preliminary checks Before beginning to install, the following is necessary: Make sure that the point where the electrical panel is anchored is free from any impacts, and that the surface is solid and that proper tools and materials are used (i.e.
  • Page 5: Electrical Connections

    6 Electrical connections Gearmotor FERNI and EMEGA The ADT card should be fastened to the gearmotor terminals as shown, and connected to the control panel on terminals M, N and R (the RA terminal is not active on the FERNI and EMEGA models). FERNI EMEGA RC FA...
  • Page 6 Power supply Terminals for powering accessories: Power supply to the - at 24 V (AC) powered with 230 V (AC) 230V AC 50/60 Hz - at 24 V (AC) powered with 24 V (AC) control panel Overall allowed power: 40 W Electro lock connection (12V-15 W max.) with EMEGA9 Lighting and warning devices...
  • Page 7 Command devices Stop button ((N.C.) contact.) Gate stop button with exclusion of automatic closing, to resume movement press command button or transmitter button. If unused, set DIP-switch 9 to ON. Key switch selector and/or opening button (N.O. contact) - Command for gate opening. Key switch selector and/or command button (N.O.
  • Page 8 6.1 Configuring the LB18 terminals If using the LB18 battery recharger card, remove all bridges and connect the card as shown in the accompanying literature. Factory configuration Detail of the ZL170N/EMEGA combination with the E881 electro-lock To power the E881 lock with 24V on terminals 11-S (which are normally at 12V) do the following to the bridges: fig.
  • Page 9: Selecting Functions

    7 Selecting functions 10-WAY DIP-SWITCH 1 ON Automatic closing activated ; 2 ON Operating the activated “open/close/invert” " button or radio command ; 2 OFF - Operating the activated “open/stop/close/stop” " button or radio command ; 3 ON Operating the activated "open only" ” radio command ; 4 ON Prefl...
  • Page 10 8.3 Opening / closing strike zone adjustment trimmer + OP TIME - After setting up the deceleration spaces (see fig. C) 3) follow the "adjusting micro-switches" procedure in the gearmotor manual, and do the following: • set up a 60 mm X 30 mm template - keep it pressed agains one of the two strike plates as shown in fi g. 1 ( - it should be adjusted on either the opening or closing strike plate ).
  • Page 11 8.4 Opening/closing and develeration speeds To adjust the travel and deceleration speeds, shift the fastons to the spefically shown transformer connectors. Deceleration adjusting faston 230V min/max 230V RALL.MIN RALL.MAX VEL.MIN VEL.MAX Gate travel speed adjusting faston: min/max 9 Amperometric Sensor The control panel featrure an amperometric motor sensor that is triggered when an obstacle blocks its movement when opening or closing.
  • Page 12: Activating The Radio Command

    10 Activating the radio command Antenna N.O. contact output: it closes for 3 seconds every time an opening com- mand is given Contact rated for: 5A-250V a..C Connect antenna cable to the apposite terminals. Jumper in position B - Radio receiver's second channel output (N.O.) contact rated: 1A-24V d.c.
  • Page 13 Radio frequency card Only for the AF43S / radio-frequency cards: - position jumper as shown depending on the series of transmitters you are using. Frequency Card Series Radio-frequency transmitters FM 26,995 AF130 FM 30.900 AF150 AM 26.995 AF26 AM 30.900 AF30 AM 433.92 AF43S / AF43SM...
  • Page 14 Memorisation CH1 = Channel for direct commands to a gearmotor card's function (for the command type see DIP-switches 2 and 3). CH2 = Channle for direct commands to a accessory device connected to B1-B2 (can be activated via jumper, see p. 13). N.B.: If you later wish to change code, just repeat the above sequence.
  • Page 15: Dismantling And Disposal

    UNI EN ISO 14001 standard to ensure environmental protection. Please help us to safeguard the environment. At CAME we believe this to be one of the fundamentals in its market operations and development strategies. Just follow these short disposal instructions: DISPOSING OF THE PACKAGING The components of the packaging (i.e.
  • Page 16 127273, Moscow Moscow (+34) 91 52 85 009 (+7) 495 739 00 69 (+34) 91 46 85 442 (+7) 495 739 00 69 (ext. 226) CAME United Kingdom Ltd. CAME United Kingdom Ltd. GREAT BRITAIN PORTUGAL CAME Portugal CAME Portugal...