By activating the following procedure, the system returns to the factory default settings.
!
This procedure must therefore only be used in case of need, before programming the
To reset the system proceed as follows:
!
Switch-off the
system
!
S
hort-circuit the RED and BLACK wires of the 2-pin
!
Switch the
system ON
turn indicators will flash 4 times
!
Remove the previously created short-circuit; the status LED lights up steady.
!
Turn ignition key "ON";
approx. 3 seconds
!
Turn ignition key "OFF";
Current absorption @ 12Vdc with system armed and LED flashing
Maximum positive current output when armed (+A)
16.0 - SYSTEM RESET
system or auto-learning the turn indicator flashes.
power supply
.
; once the alarm system is powered, 4 acoustic signals will sound and the
.
reset is confirmed by an aucoustic signal and the wailing of the siren for
.
the LED will turn OFF. There are no acoustic signals
17.0 - TECHNICAL SPECIFICATIONS
Power supply 823 - 822
Working temperature range
Turn signals relay contact capacity
Engine immobiliser relay contact capacity
Alarm cycle duration
Additional siren output current capacity
LED
connector
.
INSTALLER MANUAL - PAGE 15
.
12 Vdc
15mA
From -30°C to +70°C
8 A at 20°C
8 A at 20°C
30 sec.
700 mA