Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
13. Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. The guarantee is valid only on presentation of the guar-
antee card completed by the dealer (see back) confirming date of
purchase or the receipt.
• The guarantee covers the device. Batteries and packaging are
not included.
• Opening or altering the device invalidates the guarantee.
• The guarantee does not cover damage caused by improper
handling, discharged batteries, accidents or non-compliance
with the operating instructions.
Please contact Microlife-service.

14. Technical Specifications

Type:
Non Contact Thermometer NC 150
Measurement
Body mode: 34.0-42.2 °C / 93.2-108.0 °F
range:
Object mode: 0-100.0 °C / 32-212.0 °F
Resolution:
0.1 °C / °F
Measurement
Laboratory:
accuracy:
±0.2 °C, 36.0 ∼ 39.0 °C / ±0.4 °F, 96.8 ∼ 102.2 °F
Display:
Liquid Crystal Display, 4 digits plus special icons
Acoustic:
The unit is turned ON and ready for the measure-
ment: 1 short beep.
Complete the measurement: 1 long beep (1 sec.) if
the reading is less than 37.5 °C / 99.5 °F, 10 short
«beep» sounds, if the reading is equal to or greater
than 37.5 °C / 99.5 °F.
System error or malfunction: 3 short «bi» sounds.
Memory:
30 readings recall in the memory mode with a
record of both time and date.
Backlight:
The display light will be GREEN for 4 seconds,
when the unit is turned ON.
The display light will be GREEN for 5 seconds,
when a measurement is completed with a reading
less than 37.5 °C / 99.5 °F.
The display light will be RED for 5 seconds, when
a measurement is completed with a reading equal
to or higher than 37.5 °C / 99.5 °F.
NC 150
Operating
Body mode: 16-40.0 °C / 60.8-104.0 °F
conditions:
Object mode: 5-40.0 °C / 41-104.0 °F
Storage
-20 - +50 °C / -4 - +122 °F
conditions:
15-95 % relative maximum humidity
Automatic
Approx. 1 minute after last measurement has been
Switch-off:
taken.
Battery:
2 x 1.5 V alkaline batteries; size AAA
Battery
approx. 2000 measurements
lifetime:
(using new batteries)
Dimensions: 141.1 x 43.3 x 36.9 mm
Weight:
90 g (with batteries), 67 g (w/o batteries)
IP Class:
IP21
Reference to
ASTM E1965; IEC 60601-1; IEC 60601-1-2 (EMC);
standards:
IEC 60601-1-11
Expected
service life: 5 years or 12000 measurements
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
According to the Medical Product User Act a biennial technical
inspection is recommended for professional users. Please
observe the applicable disposal regulations.
15. www.microlife.com
Detailed user information about our thermometers and blood pressure
monitors as well as services can be found at www.microlife.com.