To turn on the thermometer, press the ON/OFF button ; a short beep signals «thermometer ON». A display test is performed. All segments should be displayed.
Then at an ambient temperature of less than 32°C, an «L» and a flashing «°C» appear at the display field . The thermometer is now ready for use.
Correct functioning of the thermometer is tested automatically each time it is turned on. If a malfunction is detected (measurement inaccuracy), this is indicated by «ERR» on the display, and a measurement becomes impossible. In this case, the thermometer must be replaced.
Choose the preferred measuring method. When taking a measurement, the current temperature is continuously displayed and the «°C» symbol flashes. If the beep is heard 10 times and the «°C» is no longer flashing, this means that the measured increase in temperature is less than 0.1°C in 16 seconds.
To prolong the battery life, turn off the thermometer by briefly pressing the ON/OFF button . Otherwise the thermometer will automatically turn off after about 10 minutes.
If the ON/OFF button is pressed for more than 3 seconds when turning on the thermometer, the automatically stored maximum temperature during the last measurement will be displayed. At the same time, a «M» for memory will appear on the display. About 2 seconds after the button is released, the temperature value disappears and the thermometer is ready for measurement.
Microlife UAB, P. Lukšio g. 32
08222 Vilnius, Lithuania
Microlife AG, Espenstrasse 139
9443 Widnau / Switzerland
For disinfection in home use environment, use a 70% Isopropyl alcohol swab, or a cotton tissue moistened with 70% Isopropyl alcohol to wipe surface pollutants off the thermometer probe (note: consider the application and safety instruction of the disinfectant manufacturer). Always start wiping from the end of the thermometer probe (approx. at the middle of the thermometer) towards the thermometer tip. Afterwards the entire thermometer probe (see number in the drawing) should be immersed in 70% Isopropyl alcohol for at least 5 minutes (max. 24 hours). After immersion, let the disinfectant dry off for 1 minute before next use. Avoid immersing or wiping the display to protect it from fading.
The thermometer is not intended for professional use.
When the «» symbol (upside-down triangle) appears in the display, the battery is flat and needs replacing. To replace the battery remove the battery compartment cover
from the thermometer. Insert the new battery with the + at the top. Make sure you have a battery of the same type to hand. Batteries can be purchased at any electrical store.
Type: | Maximum thermometer |
Measurement range: | 32.0°C to 43.9°C Temp. < 32.0°C: display «L» for low (too low) Temp. > 43.9°C: display «H» for high (too high) |
Measurement accuracy: | ± 0.1°C; 34°C - 42°C ± 0.2°C; 32.0 - 33.9°C and 42.1 - 43.9°C |
Operating conditions: | 10 - 40°C; 15-95% relative maximum humidity |
Storage conditions: | -25 - +60°C; 15-95% relative maximum humidity |
Battery: | LR41 (1.5V) / SR41 (1.55V) |
Battery lifetime: | approx. 4500 measurements (using a new battery) |
IP Class: | IP22 |
Reference to standards: | EN 12470-3, clinical thermometers; ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 |
Expected service life: | 5 years or 10000 measurements |
This device complies with the requirements of the Medical Device Directive 93/42/EEC.
Technical alterations reserved.
This device is covered by a lifetime guarantee from the date of purchase. During this guarantee period, at our discretion, Microlife will repair or replace the defective product free of charge.
Opening or altering the device invalidates the guarantee.
The following items are excluded from the guarantee:
Should guarantee service be required, please contact the dealer from where the product was purchased, or your local Microlife service. You may contact your local Microlife service through our website: www.microlife.com/support
Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within guarantee does not prolong or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the 16F1 and is the answer not in the manual?
Questions and answers