2.3

Junction Box VR-7022F

To connect the float-free data recording unit VR-7021F to the DCU, use the junction
box VR-7022F.
FR-FTPC-CY cable
To the DCU (J21)
To the DCU (J312)
DPYCY-1.5 cable
1. Remove four screws to remove the cover from the junction box.
2. Unfasten three cable glands, then pass each cable through the cable entrance.
3. Fabricate the cables.
• DPYCY-1.5 cable
Cable jacket
Cable jacket
Vinyl tape (width: 10)
• FR-FTPC-CY cable
Cable jacket
Cable jacket
Vinyl tape (width: 10)
• Float-free DRU cable
Cable jacket
Cable jacket
Vinyl tape (width: 10)
Twist the wires.
Vinyl sheath
Cut the unused wires.
Vinyl sheath
Vinyl sheath
2. WIRING
Float-free DRU cable
To the float-free DRU
2-13