Specifications; Environmental Specifications - AEMC CA811 User Manual

Table of Contents

Advertisement

Light Conversion Formulas 1 foot-candle (lumens/foot
The Inverse-square Law
The inverse-square law states that the illuminant E at a point on a surface
varies directly with the intensity I of a point source, and inversely as the square
of the distance d between the source and the point. If the surface at the point is
normal to the direction of the incident light, the law is expressed by E=I/d
Cosine Law
The cosine law states that the illuminant on any surface varies with the cosine
of the angle of incidence. The angle of incidence q is the angle between the
normal to the surface and the direction of the incident light. The inverse-square
low and the cosine law can be combined as E=(I cos q) /d
3.1

Environmental Specifications

Range (CA811): 20 lux, 200 lux, 2000 lux, 20k lux
Range (CA813): 20 lux, 200 lux, 2000 lux, 20k lux, 200k lux
Resolution: 0.01 lux, 0.01 fc
Accuracy (Type A 2856K light source): ±5% ± 10cts
Accuracy for Common Light Sources (CA811): ±18% ± 2cts
Accuracy for Common Light Sources (CA813): ±11% ± 2cts
Cosine Angle: ƒ'
Spectral Response: CIE photopic curve
Spectral Accuracy (CA811): ƒ'
Spectral Accuracy (CA813): ƒ'
6
Shop for AEMC products online at:
CHAPTER 3

SPECIFICATIONS

1 lux (lumens/meter
20 fc, 200 fc, 2000 fc, 20k fc
20 fc, 200 fc, 2000 fc, 20k fc
<2% cosine corrected (150°)
2
<15%
1
<8%
1
ShopAEMC
www.
) = 0.0929 foot-candles
2
Lightmeter Models CA811 and CA813
.com
) = 10.764 lux
2
.
2
.
2
1.877.766.5412

Advertisement

Table of Contents
loading

Table of Contents