ALTV248UL Series
CCTV Power Supplies

Installation Guide

Models Include:
• ALTV248UL
- 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA).
- Eight (8) Fuse Protected Outputs.
• ALTV248175UL
- 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA).
- Eight (8) Fuse Protected Outputs.
• ALTV248300UL
- 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA).
- Eight (8) Fuse Protected Outputs.
• ALTV248300ULM
- 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA).
- Eight (8) Fuse Protected Outputs.
• ALTV248600UL
- 24VAC @ 25 amp (600VA)
or 28VAC @ 20 amp (560VA).
- Eight (8) Fuse Protected Outputs.
• ALTV248ULCB
- 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA).
- Eight (8) PTC Protected Outputs.
• ALTV248175ULCB
- 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA).
- Eight (8) PTC Protected Outputs.
• ALTV248300ULCB
- 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA).
- Eight (8) PTC Protected Outputs.
• ALTV248300ULCBM
- 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA).
- Eight (8) PTC Protected Outputs.
• ALTV248600ULCB
- 24VAC @ 25 amp (600VA)
or 28VAC @ 20 amp (560VA)
- Eight (8) PTC Protected Outputs.
Rev. 040506X

Advertisement

loading
Need help?

Need help?

Do you have a question about the ALTV248UL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altronix ALTV248UL

  • Page 1: Installation Guide

    ALTV248UL Series CCTV Power Supplies Installation Guide Models Include: • ALTV248UL • ALTV248ULCB - 24VAC @ 3.5 amp (85VA) - 24VAC @ 3.5 amp (85VA) or 28VAC @ 3 amp (85VA). or 28VAC @ 3 amp (85VA). - Eight (8) Fuse Protected Outputs.
  • Page 2 Overview: These Altronix CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse or PTC protected outputs for powering CCTV Cameras, heaters and other video accessories. Eight (8) Output ALTV248UL Reference Chart: Altronix Model Number 24VAC 3.5 amp 5 amp/ 3.5 amp/...
  • Page 3: Specifications

    Installation Instructions: 1. Mount unit in desired location. 2. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or ALTV248ULCB (Figs. 1, 2, pg. 5). Set power disconnect circuit breaker to OFF position for all other models (Figs.
  • Page 4: Terminal Identification

    Terminal Identification: PD4 - Power Distribution Module 1P - 4P AC output. 1N - 4N AC output. PD8 - Power Distribution Module 1P - 8P AC output. 1N - 8N AC output. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated “DANGEROUS VOLTAGE”...
  • Page 5 Fig. 1 ALTV248UL 24VAC or 28VAC output 1 (Follow same procedure using terminals 2P & N F U S E D P O W E R O U T P U T S through 8P & N outputs 2 through 8)
  • Page 6 Fig. 3 ALTV248175UL Fig. 3A 24VAC or 28VAC output 1 (Follow same procedure using terminals 2P & N F U S E D P O W E R O U T P U T S through 8P & N outputs 2 through 8) C O M M O N P O W E R O U T P U T S...
  • Page 7 Fig. 5 ALTV248300UL 24VAC or 28VAC output 1 (Follow same procedure using Fig. 5A terminals 2P & N F U S E D P O W E R O U T P U T S through 8P & N outputs 2 through 8) INPUT C O M M O N P O W E R...
  • Page 8 Fig. 7 ALTV248300ULM Fig. 7A Illuminated Power Disconnect Circuit Breaker with manual reset Transformer underneath power supply board Black Lead XFMR* 115VAC Input, 50/60 Hz. White Lead Fig. 8 Fig. 8A ALTV248300ULCBM Illuminated Power Disconnect Circuit Breaker with manual reset Transformer underneath power supply...
  • Page 9 Fig. 9 ALTV248600UL 24VAC or 28VAC fused ( Follow same procedure using terminals 2P & N thru 4P & N outputs 2 thru 4). MAIN FUSE Connected to Door Class 1 outputs Fig. 9A non-power limited Illuminated Power Disconnect Circuit Breaker with manual reset non-power limited Green Lead...
  • Page 10 Fig. 10 ALTV248600ULCB 24VAC or 28VAC output 1 (Follow same procedure using terminals 2P & N through 4P & N outputs 2 through 4) Connected to Door 24VAC configuration Class 2 Not Wet/Class 3 Wet Fig. 10A non-power limited Illuminated Power Disconnect Circuit Breaker with manual reset non-power limited Green...
  • Page 11 Enclosure Dimensions for: • ALTV248UL • ALTV248ULCB 7.25” 3.625” 8.5"H x 7.5"W x 3.5"D 1.25” 3.50” 1.25” 0.60” 6.05” 0.60” 1.125” 1.125” 2.00” 2.00” 8.125” 1.00” 1.00” 0.60” 6.05” 0.60” 1.25” 3.50” 3.50” 1.00” 1.00” 5.25” 1.00” Enclosure Dimensions for: •...
  • Page 12 1.00” 10.50” 1.00” Altronix is not responsible for any typographical errors. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. II1ALTV248ULSeries D05F MEMBER - 12 -...