MCA 15 - MCA 25 MCA 25/28 MI
4.7
Gas connection
29/04/2010 - 300022146-001-B
The diameters of the pipes must be defined in accordance
with the standards in force in your country.
g
Connection by internal brazing ∅ 18 mm
1. Connect the gas inlet pipe.
T001621-A
WARNING
4
4
4
CAUTION
4
4
4
Close the main gas valve before starting work on the
gas pipes.
Before mounting, check that the gas meter has
sufficient capacity. To do this, you should bear in
mind the consumption of all domestic appliances.
If the gas meter has too low a capacity, inform the
energy supply company.
Ensure that there is no dust in the gas pipe. Blow into
the pipe or shake it before mounting.
We recommend installing a gas filter on the gas pipe
to prevent clogging of the gas valve unit.
Connect the gas pipe in accordance with prevailing
standards and regulations.
4. Installation