Deletion Of Sensors From The Memory In The Pcb; Deleting The Iobl 3Wv Modules From The Memory In The Pcb - DeDietrich Innovens MCA 15 Installation And Service Manual

Wall-hung gas condensing boilers
Hide thumbs Also See for Innovens MCA 15:
Table of Contents

Advertisement

MCA 15 - MCA 25 MCA 25/28 MI
Faults
Code Cause
5 RESET:ON/OFF
D32
TA-S SHORT-CIR
D37
TA-S DISCONNEC
D38
29/04/2010 - 300022146-001-B
Description
of the
error
SCU
5 resets done in less than an hour
Switch the boiler off and switch back on
4
SCU
The Titan Active System® is short-circuited
Check that the connection cable between the SCU PCB and the anode is not short-
4
circuited
Check that the anode is not short-circuited
4
Remarks:
Domestic hot water production has stopped but can nonetheless be restarted using key
r.
The tank is no longer protected.
If: A tank without Titan Active System® is connected to the boiler: Check that the Titan
Active System® simulation connector (delivered with package AD212) is fitted to the
sensor card.
SCU
The Titan Active System® is on an open circuit
Check that the connection cable between the SCU PCB and the anode is not severed
4
Check that the anode is not broken
4
Remarks:
Domestic hot water production has stopped but can nonetheless be restarted using key
r.
The tank is no longer protected.
If: A tank without Titan Active System® is connected to the boiler: Check that the Titan
Active System® simulation connector (delivered with package AD212) is fitted to the
sensor card.
8.3.1.
The configuration of the sensors is memorised by the SCU PCB. If a
sensor error appears whilst the corresponding sensor is not
connected or has been voluntarily removed, please delete the sensor
from the memory in the SCU PCB.
4 Press key ? repeatedly until "Do you want to delete this
4 Select YES by turning the rotary button and press to confirm.
8.3.2.
The configuration of the IOBL 3WV modules is memorised by the
SCU PCB. If a IOBL.3WV B DEF or IOBL.3WV C DEF error appears
after voluntary deletion of a 3WV module, please delete the module
from the memory in the SCU PCB.
4 Press key ? repeatedly until "Do you want to delete this
4 Select YES by turning the rotary button and press to confirm.
Checking / solution
Deletion of sensors from the memory in the
PCB
sensor?" is displayed.
Deleting the IOBL 3WV modules from the
memory in the PCB
module?" is displayed.
8. Troubleshooting
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Innovens mca 25/28 miInnovens mca 25

Table of Contents