Harmonic currents with 1% mains impedance.
Table 2-1
Single Phase 115 V Connection
MLFB
Filter Type
6SE6410-2UA11-2AA0 UNFILTERED
6SE6410-2UA12-5AA0 UNFILTERED
6SE6410-2UA13-7AA0 UNFILTERED
6SE6410-2UA15-5BA0 UNFILTERED
Table 2-2
Single Phase 230 V Connection
MLFB
Filter Type
6SE6410-2BB11-2AA0
6SE6410-2UB11-2AA0
UNFILTERED
6SE6410-2BB12-5AA0
6SE6410-2UB12-5AA0
UNFILTERED
6SE6410-2BB13-7AA0
6SE6410-2UB13-7AA0
UNFILTERED
6SE6410-2BB15-5BA0
6SE6410-2UB15-5BA0
UNFILTERED
6SE6410-2BB17-5BA0
6SE6410-2UB17-5BA0
UNFILTERED
2.5
Derating with Pulse Frequencies
Table 2-3
Power
(kW)
0.12
0.25
0.37
0.55
(115V,50°C)
0.55
(115V,40°C)
0.75
0.75 (40º C)
All currents are rated at 50 ºC unless otherwise stated
MICROMASTER 410
Operating Instructions
6SE6400-5EA00-0BP0
Power
Fundamen-
CT (kW)
tal Amps
0,12
0,25
0,37
0,55
11,25
Power
Fundamen-
CT (kW)
tal Amps
B
0,12
B
0,25
B
0,37
B
0,55
B
0,75
Derating with Pulse Frequencies
4 kHz
6 kHz
0.9
0.9
1.7
1.7
2.3
2.3
3.0
3.0
3.2
3.2
3.9
3.9
4.2
4.2
rd
th
3
5
Amps
Amps
Amps
2,90
2,80
2,60
5,65
5,30
4,68
7,94
7,32
6,07
10,10
8,06
rd
th
3
5
Amps
Amps
Amps
1,34
1,20
0,83
2,90
2,40
1,70
4,10
3,50
2,50
5,30
4,60
3,30
7,30
6,50
4,40
Measured Output Current (A)
8 kHz
10 kHz
12 kHz
0.9
0.8
1.7
1.5
2.3
2.0
2.7
2,5
3.2
2.9
3.6
3.2
4.2
3.8
2 Installation
th
th
th
th
7
9
11
13
Amps
Amps
Amps
2,35
2,00
1,68
1,30
3,80
2,87
1,98
1,27
4,57
3,05
1,87
1,24
5,67
3,50
2,00
1,58
th
th
th
th
7
9
11
13
Amps
Amps
Amps
0,45
0,18
0,12
0,06
0,95
0,40
0,20
0,20
1,40
0,60
0,25
0,25
1,80
0,70
0,40
0,40
2,50
1,00
0,50
0,50
14 kHz
16 kHz
0.7
0.6
0.5
1.3
1.1
0.9
1.7
1.5
1.3
2.2
2.0
1.7
2.6
2.3
2.0
2.9
2.6
2.3
3.4
3.0
2.7
21