Table 9-3 Case 3 - Filtered For Residential, Commercial And Light Industry; Table 9-4 Compliance Table - Siemens micromaster 410 Operating Instructions Manual

Table of Contents

Advertisement

9 Electro-Magnetic Compatibility
Case 3: Filtered - for residential, commercial and light industry
This level of performance will allow the manufacturer / assembler to self-certify
compliance of their apparatus with the EMC directive for the residential,
commercial and light industrial environment as regards the EMC performance
characteristics of the power drive system. Performance limits are as specified in
the generic emission and immunity standards EN 50081-1 and EN 50082-1.
Table 9-3
EMC Phenomenon
Emissions:
Radiated Emissions*
Conducted Emissions
Immunity:
Supply Voltage Distortion
Voltage Fluctuations, Dips, Unbalance,
Frequency Variations
Electrostatic Discharge
Burst Interference
* These limits are dependent on the inverter being correctly installed inside a
metallic switchgear enclosure. The limits will not be met if the inverter is not
enclosed.
NOTICE
To achieve these performance levels, you must not exceed the default Pulse
frequency nor use cables longer than 5 m (16.40 ft).
Table 9-4
Model
Case 1 – General Industrial
6SE6410-2U***-**A0
Case 2 – Filtered Industrial
6SE6410-2B***-**A0
72
Case 3 - Filtered for Residential, Commercial and Light Industry
Standard
EN 55022
EN 61800-3
EN 61000-2-4
EN 61000-2-1
EN 61000-4-2
EN 61000-4-4
Compliance Table
Remarks
Unfiltered units, all voltages and powers. The product standard EN 61800-3
+ A11 for "Adjustable speed electrical power drive systems – Part3: EMC
product standard including specific test methods" specifies limits for
conducted emissions, which cannot be matched from unfiltered inverters in
nd
the 2
environment.
If compliance with the product standard is required, filtered inverters ( as
described under case 2) have to be installed.
All units with integral filters for screened motor cables up to 10 m (32,80 ft)
[Class A]
Level
Level for equipment class B
category C1: level according EN 55011,
class B
category C2: level according EN55011,
class A
8 kV air discharge
2 kV power cables (Level 3),
2 kV control (Level 4)
MICROMASTER 410
Operating Instructions
6SE6400-5EA00-0BP0
Issue 04/02