Huawei SmartAX MA5603T Configuration Manual page 1114

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Item
Common
parameter
Issue 01 (2014-04-30)
Terminal ID (H248)
User priority
User type
system parameter
Overseas parameters
POTS port attributes
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12 FTTO Configuration(SOHO and SME)
Description
If the TID template with which the POTS
user is bound does not support terminal
layering, this parameter needs to be
configured.
According to the service requirements, user
priorities must be specified. The user
priorities include the following:
l cat1: government1 (category 1
government users)
l cat2: government2 (category 2
government users)
l cat3: common (common users)
According to the service requirements, user
type needs to be specified. The user type
includes the following:
l DEL: direct exchange lines (default)
l ECPBX: earth calling PBX
l LCPBX: loop calling PBX
l PayPhone: pay phone
The system parameters including the
overseas version flag and message waiting
indication (MWI) mode need to be
configured according to the local standard to
ensure that the response of the user terminal
complies with the local standard.
The attributes such as the upper and lower
thresholds of the flash-hooking duration
need to be configured according to the local
standards to ensure that the response of the
user terminal complies with the local
standards.
If the POTS port needs to support the polarity
reversal accounting, the POTS port needs to
be configured to support the polarity reversal
pulse. Other attributes do not need to be
modified if there is no special requirement.
1089

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents