mr. steam MS-225E Installation, Operation And Maintenance Manual

mr. steam MS-225E Installation, Operation And Maintenance Manual

Steambath generator systems

Advertisement

Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential Models: 90E – 400E and Super 1E – 6E
.
mr
steam
®
Feel Good Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-225E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mr. steam MS-225E

  • Page 1 Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: 90E – 400E and Super 1E – 6E steam ® Feel Good Inc.
  • Page 2 When installing and using this electrical equipment, basic safety precautions R E D M E F I R S T ! should always be followed, including the following: IMPORT NT NOTE: s you follow these IMPORT NT S FETY INSTRUCTIONS instructions, you will notice warning and cau- tion symbols.
  • Page 3: Table Of Contents

    _______________________________ & INST LL TION OPER TION M INTEN NCE M NU L MODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E, SERI L NO. ___________________________ MS-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E T BLE OF CONTENTS Read Me First! & Warning Sticker ..Inside front cover Select Your Mr.Steam Model .
  • Page 4 ‡Wire size ( WG) based on minimum 90˚C rated THHN copper conductors. Refer to the National Electrical Code for other types of conductors. See Mr. Steam® Installation and Operation Manual for complete dimensional and installation information. MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus Control, and two matching steamheads.
  • Page 5: Before Installing

    Mr. Steam parts Mr.Steam steam generators are intended to be operated with Mr.Steam may result in property damage or in a hazardous condition.
  • Page 6 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ W TER QU LITY INFORM TION or optimum results, the water supply should be tested prior RECOMMENDED FEEDW TER QU LITY to installation. If the mineral content exceeds the following Hardness, ppm 8 –...
  • Page 7: Typical Installation Instructions

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ TYPIC L MR.STE M INST LL TION C UTION The control features an integral NOTE: Drawings for illustrative purposes only. temperature sensor. Locate the control in a location Consult with qualified designer, architect or representative of the desired steambathing temper- contractor for steam room construction details.
  • Page 8 D R I P P N Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Check local plumbing codes for receptor, trap and vent requirements. Drip pans drain by gravity. The drip pan is equipped with an integral 3 / 4 "...
  • Page 9 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INST LLING THE ROUND OR SQU RE 1/8" minimum clearance required ( 1 ⁄2" NPT) ROM STE M STE MHE D when Acrylic Shield is used. Use Teflon ® See installation instructions provided equal sealant on with the Acrylic Shield.
  • Page 10 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ GENER TOR DI GR M Water Inlet Control & Accessory Connections Steam Outlet Safety Valve Optional AutoFlush Manual Drain Valve 12” ” for servicing IMPORT NT NOTES: Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing.
  • Page 11: Field Power Wiring

    1. Check power voltage. Use 240V rated unit when sup- ____________________________________________________________ ____________________________________________ ply is greater than 208V. (Most homes have 240V, 1PH MS-225E service). Use 208V rated unit for 208V power. 2. Use minimum 90˚ C/300V rated insulated copper ____________________________________________________________ ____________________________________________...
  • Page 12 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SINGLE PH SE 208/240 VOLT WIRING DI GR MS POWER INPUT L E G E N D TRANSFORMER (All Diagrams) FIELD MODELS MS90E, MS150E, WIRING FACTORY MS225E, MS400E WIRING WATER FEED SOLENOID GROUND...
  • Page 13: Optional Tandem Cable

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INST LL TION INSTRUCTIONS FOR MODELS: MS-SUPER 4E, MS-SUPER 5E ND MS-SUPER 6E 1. Install each unit as in a single installation. Install the two generators as close to each other as possible. 2.
  • Page 14: Troubleshooting

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INITI L ST RT-UP ND CHECKOUT 1. Turn on control. Follow specific instructions provided with controls. 2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head. Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point.
  • Page 15: System Status Codes

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SYSTEM ST TUS CODES The control (either iSteam ® , iTempo or iTempo/Plus ) may display a status code if the steam generator is not functioning properly. ™ ™ Code Code Meaning Probable Cause Suggested Remedy...
  • Page 16 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ ® OPTION L UTOFLUSH Steam Generator Box Contents 3 Pin Connector for utoFlush utoFlush Valve with Cord Installation Instructions. OPER TION The optional utoFlush System feature automatically drains the Mr.Steam generator following each use. time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
  • Page 17 Installation, Operation & Maintenance Manual __________________________________________________________________________ OPTION L DRIP P N Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Locate the drip pan on a solid level surface and place the steam generator inside the drip pan. Insure the steam generator is level (see page 4 for locating the steam generator).
  • Page 18 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ P RTS IDENTIFIC TION DI GR M Contactor Liquid Level Control Board MS REGUL R MODELS Transformer Water Feed Liquid Level Probe Solenoid MS65E - MS400E Power Supply (with utoFlush ™...
  • Page 19 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ REPL CEMENT P RTS LIST __________________________________________________________________________________________ Part No. Description Generator ___________________________________________________________________________________________ 99178MS Drain Valve ll Models 99297 Safety Valve 15PSI ll Models 100479 Water Feed Solenoid Valve w/filter ll Models 10477-3 Transformer 24V C ll Models...
  • Page 20: Control Inst Ll Tion

    The iSteam ® , iTempo and iTempo/Plus controls Mr. Steam technical service representative if a 60 foot cable is ™ ™ are designed to be installed inside or outside the required. steam room as a matter of personal preference. If the...
  • Page 21 Do not alter or modify any Mr. Steam products including the steam generator, iSteam, iTempo/Plus, iTempo, iGenie or HomeWizard controls. Doing so may result in an inoper-...
  • Page 22 mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ ® USING MR.STE M ESSENTI L OILS njoy romaSteam essential oils by placing a drop or two into an unheated romaSteam steamhead as shown in the AromaSteam illustration. Only use Mr.Steam romaSteam essential oils 10ml bottle in the Mr.Steam romaSteam steamhead.
  • Page 23 Failure to allow the water to cool will expose the equipment and user to scalding water and cause property and personal injury. W RR NTY To view or download the Mr. Steam Residential Generator Warranty and register your Product go to: blog.mrsteam.com/wr...
  • Page 24 steam ® Feel Good Inc. www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STE M (East Coast) or 1.800.72.STE M (West Coast) for more information. steam ® Sussman- utomatic Corporation I hello@mrsteam.com I www.mrsteam.com ®...

Table of Contents