Page 1
Installation, Operation & Maintenance Manual Steam@Home ® RESIDENTIAL STEAM GENERATOR SYSTEMS Models: SAH3000, SAH4500, SAH6000 steam Feel Good Inc. ®...
Page 2
READ ME FIRST! states a hazard may cause serious injury WA RN ING or death if precautions are not followed. IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols. This blocked informa- signals a situation where minor injury or C A U TI ON tion is important for the safe and efficient installation, operation product damage may occur if you do not follow instructions.
Steam@home ® Residential Steambath Generator Systems INSTALLATION OPERATION & MAINTENANCE MANUAL MODELS: SAH3000, SAH4500, SAH6000 MODEL ____________________ SERIAL NO.____________________ TABLE OF CONTENTS _______________________________________________________________ Information for Installers & Homeowners Read Me First! & Warning Sticker......1 Select Your MrSteam Model.
Page 4
MrSteam MS series of residential steam bath generators glass enclosures for recommended steamhead location. Use supplied Acrylic Shield PN MS-103938. See ** For all other room materials refer to Mr. Steam MS series instructions on page 7. of residential steam bath generators...
• Insure steambath generator has been correctly sized for the steambath room. Pay particular attention to room volume and Never use damaged equipment, construction. If any questions, please refer to Mr. Steam sizing W AR N IN G doing so may result in an inoperative or hazardous and selection guide on page 2.
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ WATER QUALITY INFORMATION IMPORTANT NOTE: For optimum results, the water supply should be tested prior to initial startup. If the mineral con- tent exceeds the following recommended limits, various external treatment processes may be used to correct the problem. NOTE: An analysis of the on-site water must be made by a recognized and reliable water treatment company to ascertain the existing condition and treatment required.
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ tyPICAL Mr.StEAM INStALLAtIoN NOTE: For illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details. Provide unions to facilitate installation SteamStart Control ® and disconnect of piping See page 12 IMPORTANT NOTE: Install cable in a for installation...
Page 8
Unit drains by gravity. See page 13 for draining instructions DRIP PAN (PN 103867) Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Locate the drip pan on a solid level surface and place the steam generator inside the drip pan.
Page 9
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ Oil Well INSTALLATION OF THE STEAM HEAD ⁄ ” NPT, PN 103937) Acrylic Shield 103938) WITH ACRYLIC SHIELD (PN 103938) The Acrylic Shield (PN 103938) is for use when acrylic or other Acrylic Shield 103938) non-heat resistant materials are used for the steamroom enclosure.
Page 10
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ ELECTRICAL CHART __________________________________________________________________________ All electrical wiring to be installed by a qualified Max Room Wire Size licensed electrician in accordance with National Model Volume Volts† Phase AMPS (AWG) for up to Electrical Code and local electrical code.
All installation and service to be per- formed by qualified and licensed electricians and plumbers only. Installation or service by unquali- fied persons or failure to use Mr. Steam parts may void the warranty. StEP 1 Check your main incoming power to the unit.
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ SINGLE PHASE 208/240 VoLt WIrING DIAGrAMS SAH units are not available in 3 phase MODELS: SAH3000 L E G E N D (All Diagrams) SAH4500 FIELD SAH6000 WIRING FACTORY WIRING SteamStart™...
Page 13
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ MoDELS SAH3000, SAH4500, SAH6000 shown with cover removed Contactor Transformer Liquid Level Control Board Water Feed Solenoid Power Supply Opening SteamStart ™ Steam Outlet Safety Valve Drain Valve (shown in closed position) Heating Element Stainless Steel Tank NOTE: For ILLUStrAtIVE PUrPoSES oNLy.
® Steam@Home steam ® Installation, Operation & Maintenance Manual ________________________________________________________________________ DIMENSIONAL INFORMATION On/Off Switch STEAMSTART ® Box Contents: • SteamStart Control • Control Cable INSTALLING THE STEAMSTART ® CONTROL The SteamStart has a 30 foot cable with a Plug & Play connector at both ends.
Page 15
IMPORTANT NOTE: Do not operate any SteamStart off, press the button on the SteamStart control. control with other than a Mr. Steam SAH steam genera- The SteamStart control may blink if the steam generator is not tor. Doing so may result in an inoperative installation.
Page 16
______________________________________________________________________________________________________________________________________________ Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. ______________________________________________________________________________________________________________________________________________ steam ® ® Sussman-Automatic Corporation / hello@mrsteam.com / www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 / : 718 937 4500 : 718 472 3256 / FAX...
Need help?
Do you have a question about the Steam@Home 3000 and is the answer not in the manual?