mr. steam MS-65T Installation Operation & Maintenance

Residential steambath generator systems

Advertisement

S
Mr
team
®
Residential Steambath Generator Systems
____________________________________________________________
Installation, Operation & Maintenance Manual
A Lifetime of Pleasure
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-65T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mr. steam MS-65T

  • Page 1 team ® Residential Steambath Generator Systems ____________________________________________________________ Installation, Operation & Maintenance Manual A Lifetime of Pleasure ®...
  • Page 2: Table Of Contents

    MODELS Typical Installation ....2 MS-65T MS Super-4T, 5T, 6T Typical Installation . . . 3 Installation ......4...
  • Page 3: Before Installing

    team ® Installation, Operation & Maintenance Manual Before Installing IMPORTANT: The following general information should be used in conjunction with consultations with your architect, designer and contractor in determining all factors necessary in providing a suitable and safe steam room. Read these instructions before installation or service.
  • Page 4: Locating The Steam Generator Unit

    team ® Installation, Operation & Maintenance Manual Locating the Steam Generator Unit Select a location as near as practical to the steam room.Typical locations include: closet, vanity cabinet, heated attic or basement. 1. Locate steambath generator within 25 feet of steam room. 2.
  • Page 5 team ® Installation, Operation & Maintenance Manual MS Super 4T, 5T, 6T Typical Configuration Installation Instructions for Models: MS-Super 4T, MS-Super 5T and MS-Super 6T Printed Circuit Board 1. Install each steam generator as in a single installation. Component shown Install generators as close as possible to each other, enlarged for illustrative not exceeding 12 feet.The interconnecting cable length...
  • Page 6: Installation

    team ® Installation, Operation & Maintenance Manual Installation Plumbing All plumbing shall be performed by a qualified licnesed plumber and in accordance with applicable National and local codes. • Use unions on all pipe connections. • Use only brass piping or copper tubing •...
  • Page 7: Field Power Wiring

    team ® Installation, Operation & Maintenance Manual Field Power Wiring Models MS 65T – MS 400T Ground Lug (single phase wiring shown) Ground Contactor L1, L2, Ground Knockout by field wiring (conduit and fittings omitted for clarity) _________________________________________________ TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS !!! _________________________________________________ NOTE: For illustrative purposes only.
  • Page 8: Wiring Diagrams

    L E G E N D (All Diagrams) FIELD WIRING POWER INPUT FACTORY WIRING TRANSFORMER BLACK WHITE DARK SINGLE PHASE BLACK BLUE MS-65T, MS-90T, MS-150T, MS-225T, MS-300T, MS-400T GREEN PURPLE GROUND WHITE TO PROBE LIGHT CABLE TEMPO or BLUE TEMPO/PLUS CONTROL CONTACTOR CABLE...
  • Page 9 team ® Installation, Operation & Maintenance Manual Single Phase Wiring Diagram with TEMPO PLUS control Installation Instructions for Models: MS-Super 4T, MS-Super 5T and MS-Super 6T 1. Install each unit as in a single installation as close to each other as possible. 2.
  • Page 10 team ® Installation, Operation & Maintenance Manual Three Phase Wiring Diagram with TEMPO/PLUS control Installation Instructions for Models: MS-Super 4T, MS-Super 5T and MS-Super 6T 1. Install each unit as in a single installation as close to each other as possible. 2.
  • Page 11 team ® Installation, Operation & Maintenance Manual Optional AutoFlush System ® BOX CONTENTS: (3) Pin Connector • AutoFlush Valve with Cord for Tempo/Ext (2) Pin Connector • Installation instructions. (9) Pin Connector for AutoFlush for Tempo and Tempo/Plus Controls Operation The optional AutoFlush ®...
  • Page 12: Optional Autoflush System

    team ® Installation, Operation & Maintenance Manual Optional AutoFlush System ® (cont.) Sweat Fittings When using sweat fittings use only tin base solder with a melting point below 600 degrees F. Do not overheat. Ends of water supply tubing must be thoroughly cleaned for a minimum distance of 1"...
  • Page 13: Liquid Level Control Board

    team ® Installation, Operation & Maintenance Manual Liquid Level Control Board- Explanation of LED Indicators With TEMPO or TEMPO/PLUS control OFF ______________________________________________________________________________________ Water level indicator–LED is ON when no water is detected (for more that 5 seconds). OFF when water level is satisfactory. For units with AutoFlush, if more that two hours have elapsed since last usage and this LED is OFF it is indicative of an autoflush or water level probe circuit malfunction.
  • Page 14 team ® Installation, Operation & Maintenance Manual MS Regular Models MS 65T - MS 400T (with AutoFlush) shown with cover removed Transformer Liquid Level Water Feed Control Board Solenoid Power Block Power Supply Knock-Out Liquid Level Probe Water Feed Plug and Play Connection (see page 11) Water Feed Hose...
  • Page 15 A Division of Sussman-Automatic Corporation 43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500 • 1-800-767- 8326 • Fax: (718) 472-3256 • www.mrsteam.com Western Regional Offices: 9410 S. La Cienega Blvd., Inglewood CA 90301 • 1-800 72 STEAM (1-800 727-8326) • Fax: (310) 216-2944 Rev 6.3/03 PUR 101289...

Table of Contents