mr. steam MS-90E Installation, Operation And Maintenance Manual

mr. steam MS-90E Installation, Operation And Maintenance Manual

Steambath generator systems

Advertisement

Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential Models: MS90E – MS400E and MSSUPER1E – 6E
.
mr
steam
®
Feel Good Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-90E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mr. steam MS-90E

  • Page 1 Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: MS90E – MS400E and MSSUPER1E – 6E steam ® Feel Good Inc. ™...
  • Page 2: Important Safety Instructions

    When installing and using this electrical equipment, basic safety precautions should R E A D M E F I R S T ! always be followed, including the following: WARNING As you follow these IMPORTANT SAFETY INSTRUCTIONS instructions, you will notice warning and READ AND FOLLOW ALL INSTRUCTIONS caution symbols.
  • Page 3: Table Of Contents

    _______________________________ & INSTALLATION OPERATION MAINTENANCE MANUAL MODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E, SERIAL NO. ___________________________ MS-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E TABLE OF CONTENTS Important Safety Instructions ... . . Inside front cover Select Your Mr.Steam Model .
  • Page 4: Select Your Mr.steam Model

    ‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors. Refer to the National Electrical Code for other types of conductors. See Mr. Steam® Installation and Operation Manual for complete dimensional and installation information. MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus Control, and two matching steamheads.
  • Page 5: Before Installing

    Installation consultations with an architect, designer and contractor in determin- or service by unqualified persons or failure to use Mr. Steam parts ing factors necessary in providing a suitable and safe steam room.
  • Page 6: Water Quality Information

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ WATER QUALITY INFORMATION or optimum results, the water supply should be tested prior RECOMMENDED FEEDWATER QUALITY to installation. If the mineral content exceeds the following Hardness, ppm 8 – 85 (~0.5 – 5 gpg) recommended limits, various external treatment processes P-Alkalinity, ppm 85 –...
  • Page 7: Typical Installation Instructions

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ TYPICAL MR.STEAM INSTALLATION CAUTION The control features an integral NOTE: Drawings for illustrative purposes only. iSteam ® , iTempo ™ temperature sensor. Locate the control in a location Consult with qualified designer, architect or or iTempo/Plus ™...
  • Page 8: Installation: Plumbing, Water Supply, Drain, Steam Outlet Safety Valve, Drip Pan, Aromasteam

    D R I P PA N Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Check local plumbing codes for receptor, trap and vent requirements. Drip pans drain by gravity. The drip pan is equipped with an integral 3 / 4 "...
  • Page 9: Steam Head Installation

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INSTALLING THE ROUND OR SQUARE 1/8" minimum clearance required ( 1 ⁄2" NPT) AROMASTEAM STEAMHEAD when Acrylic Shield is used. See installation instructions provided Use Teflon ® with the Acrylic Shield. equal sealant on NOTE: A 1 ⁄...
  • Page 10: Steam Generator Dimensions

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ GENERATOR DIAGRAM Water Inlet Control & Accessory Connections Steam Outlet Safety Valve Optional AutoFlush Manual Drain Valve 12” ” for servicing IMPORTANT NOTES: Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing.
  • Page 11: Electrical Specifications & Field Power Wiring

    Ambient Ambient ____________________________________________________________ ____________________________________________ WARNING All electrical wiring to be installed by a qualified licensed electrician in accordance with MS-90E National Electrical Code and local electrical code. ____________________________________________________________ ____________________________________________ POWER WIRING MS-150E See “Field Power Wiring” Diagrams (below) 1. Check power voltage. Use 240V rated unit when supply ____________________________________________________________ ____________________________________________ is greater than 208V.
  • Page 12: Wiring Diagrams

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SINGLE PHASE 208/240 VOLT WIRING DIAGRAMS POWER INPUT L E G E N D TRANSFORMER (All Diagrams) FIELD MODELS MS90E, MS150E, WIRING FACTORY MS225E, MS400E WIRING WATER FEED SOLENOID GROUND VALVE CONTACTOR AutoFlush...
  • Page 13: Optional Tandem Cable Diagram

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INSTALLATION INSTRUCTIONS FOR MODELS: MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E 1. Install each unit as in a single installation. Install the two generators as close to each other as possible. Shock Hazard.
  • Page 14: Initial Start-Up & Checkout

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INITIAL START-UP AND CHECKOUT 1. Turn on control. Follow specific instructions provided with controls. 2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head. Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point.
  • Page 15: System Status Codes

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SYSTEM STATUS CODES The control (either iSteam ® , iTempo or iTempo/Plus ) may display a status code if the steam generator is not functioning properly. ™ ™ Code Code Meaning Probable Cause Suggested Remedy Water level is not...
  • Page 16: Optional Autoflush System

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ ® OPTIONAL AUTOFLUSH Steam Generator Box Contents 3 Pin Connector for AutoFlush AutoFlush Valve with Cord Installation Instructions. OPERATION The optional AutoFlush System feature automatically drains the Mr.Steam generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
  • Page 17: Optional Drip Pan

    Installation, Operation & Maintenance Manual __________________________________________________________________________ OPTIONAL DRIP PAN Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Locate the drip pan on a solid level surface and place the steam generator inside the drip pan.
  • Page 18: Parts Identification Diagrams

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ PARTS IDENTIFICATION DIAGRAMS Contactor Liquid Level Control Board MS REGULAR MODELS Transformer Water Feed Liquid Level Probe Solenoid MS65E - MS400E Power Supply (with AutoFlush ™ Knock-Out shown with cover removed Water Inlet Plug and Play Connection...
  • Page 19: Replacement Parts List

    mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ REPLACEMENT PARTS LIST __________________________________________________________________________________________ Part No. Description Generator ___________________________________________________________________________________________ 99178MS Drain Valve All Models 99297 Safety Valve 15PSI All Models 100479 Water Feed Solenoid Valve w/filter All Models 10477-3 Transformer 24VAC All Models 103975 Liquid Level Control Board...
  • Page 20: Control Installation

    CAUTION To avoid unintentional steambath operation, DO NOT alter or modify any Mr. Steam product. Doing so may DO NOT locate the control where other controls, acces- result in an inoperative or hazardous installation and will void sories, shower heads, valves, body sprays or similar within the UL listing and warranty.
  • Page 21: Homeowner Section

    Unconsciousness. provided on the label using permanent ink. The use of alcohol, WARNING Not Actual Size For a replacement warning drugs, or medication can greatly increase label contact Mr. Steam the risk of hyperthermia. customer service at 1-800-76-STEAM or hello@mrsteam.com...
  • Page 22: Setting Steam Bath Temperature & Duration

    To prevent slip and fall hazards non-skip strips must be installed on the steam room floor. WARNING DO NOT alter or modify any Mr. Steam product. Doing so may result in an inoperative or hazardous installation and will void the UL listing and warranty.
  • Page 23: Using The Aromasteam Essential Oils

    Tightly close bottles when storing oils. Keep bottles away from sources of ignition. All drawings are for illustrative purposes only WARRANTY To view or download the Mr. Steam Residential Generator Warranty blog.mrsteam.com/wr and register your Product go to:...
  • Page 24 steam ® Feel Good Inc. ™ www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. steam ® Sussman-Automatic Corporation I hello@mrsteam.com I www.mrsteam.com ®...