Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: MS90E – MS400E and MSSUPER1E – 6E steam ® Feel Good Inc. ™...
When installing and using this electrical equipment, basic safety precautions should R E A D M E F I R S T ! always be followed, including the following: WARNING As you follow these IMPORTANT SAFETY INSTRUCTIONS instructions, you will notice warning and READ AND FOLLOW ALL INSTRUCTIONS caution symbols.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors. Refer to the National Electrical Code for other types of conductors. See Mr. Steam® Installation and Operation Manual for complete dimensional and installation information. MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus Control, and two matching steamheads.
Installation consultations with an architect, designer and contractor in determin- or service by unqualified persons or failure to use Mr. Steam parts ing factors necessary in providing a suitable and safe steam room.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ WATER QUALITY INFORMATION or optimum results, the water supply should be tested prior RECOMMENDED FEEDWATER QUALITY to installation. If the mineral content exceeds the following Hardness, ppm 8 – 85 (~0.5 – 5 gpg) recommended limits, various external treatment processes P-Alkalinity, ppm 85 –...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ TYPICAL MR.STEAM INSTALLATION CAUTION The control features an integral NOTE: Drawings for illustrative purposes only. iSteam ® , iTempo ™ temperature sensor. Locate the control in a location Consult with qualified designer, architect or or iTempo/Plus ™...
D R I P PA N Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Check local plumbing codes for receptor, trap and vent requirements. Drip pans drain by gravity. The drip pan is equipped with an integral 3 / 4 "...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INSTALLING THE ROUND OR SQUARE 1/8" minimum clearance required ( 1 ⁄2" NPT) AROMASTEAM STEAMHEAD when Acrylic Shield is used. See installation instructions provided Use Teflon ® with the Acrylic Shield. equal sealant on NOTE: A 1 ⁄...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ GENERATOR DIAGRAM Water Inlet Control & Accessory Connections Steam Outlet Safety Valve Optional AutoFlush Manual Drain Valve 12” ” for servicing IMPORTANT NOTES: Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing.
Ambient Ambient ____________________________________________________________ ____________________________________________ WARNING All electrical wiring to be installed by a qualified licensed electrician in accordance with MS-90E National Electrical Code and local electrical code. ____________________________________________________________ ____________________________________________ POWER WIRING MS-150E See “Field Power Wiring” Diagrams (below) 1. Check power voltage. Use 240V rated unit when supply ____________________________________________________________ ____________________________________________ is greater than 208V.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SINGLE PHASE 208/240 VOLT WIRING DIAGRAMS POWER INPUT L E G E N D TRANSFORMER (All Diagrams) FIELD MODELS MS90E, MS150E, WIRING FACTORY MS225E, MS400E WIRING WATER FEED SOLENOID GROUND VALVE CONTACTOR AutoFlush...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INSTALLATION INSTRUCTIONS FOR MODELS: MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E 1. Install each unit as in a single installation. Install the two generators as close to each other as possible. Shock Hazard.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INITIAL START-UP AND CHECKOUT 1. Turn on control. Follow specific instructions provided with controls. 2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head. Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SYSTEM STATUS CODES The control (either iSteam ® , iTempo or iTempo/Plus ) may display a status code if the steam generator is not functioning properly. ™ ™ Code Code Meaning Probable Cause Suggested Remedy Water level is not...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ ® OPTIONAL AUTOFLUSH Steam Generator Box Contents 3 Pin Connector for AutoFlush AutoFlush Valve with Cord Installation Instructions. OPERATION The optional AutoFlush System feature automatically drains the Mr.Steam generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
Installation, Operation & Maintenance Manual __________________________________________________________________________ OPTIONAL DRIP PAN Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Locate the drip pan on a solid level surface and place the steam generator inside the drip pan.
CAUTION To avoid unintentional steambath operation, DO NOT alter or modify any Mr. Steam product. Doing so may DO NOT locate the control where other controls, acces- result in an inoperative or hazardous installation and will void sories, shower heads, valves, body sprays or similar within the UL listing and warranty.
Unconsciousness. provided on the label using permanent ink. The use of alcohol, WARNING Not Actual Size For a replacement warning drugs, or medication can greatly increase label contact Mr. Steam the risk of hyperthermia. customer service at 1-800-76-STEAM or hello@mrsteam.com...
To prevent slip and fall hazards non-skip strips must be installed on the steam room floor. WARNING DO NOT alter or modify any Mr. Steam product. Doing so may result in an inoperative or hazardous installation and will void the UL listing and warranty.
Tightly close bottles when storing oils. Keep bottles away from sources of ignition. All drawings are for illustrative purposes only WARRANTY To view or download the Mr. Steam Residential Generator Warranty blog.mrsteam.com/wr and register your Product go to:...
Page 24
steam ® Feel Good Inc. ™ www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. steam ® Sussman-Automatic Corporation I hello@mrsteam.com I www.mrsteam.com ®...
Need help?