7.4 Valve Drive

7.4.1 Valve protrusion – Measurement
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Sliding depth gage, 200 mm
Preparatory steps
1.
Remove igniters (→ Page 167).
2.
Remove cylinder head covers (→ Page 182).
3.
Remove sleeves (arrowed).
4.
Install barring tool (→ Page 162).
5.
Rotate crankshaft with barring tool in engine
direction of rotation until marking "OT" and
pointer are aligned.
176 | Valve Drive | MS150104/02E 2016-11
Part No.
Qty.
Y20000918
1