7.11.4 Sensors – Installation
Special tools, Material, Spare parts
Designation / Use
Torque wrench, 10–60 Nm
Ratchet adapter
Assembly compound (Kluthe Hakuform 30-15)
O-ring
Sealing ring
Sealing ring
Installing NOx sensor (B88)
Note:
After being exposed to any impact, the sen-
sor is considered to be faulty and may not be
used.
1.
Only remove protective cap from thread im-
mediately before assembly.
Note:
Do not wipe off thread grease of manufactur-
er. If necessary, coat thread with high-tem-
perature anti-corrosion thread grease. Too
much grease can contaminate the sensor
during operation. Remove and mount the
sensor twice at the most.
2.
Manually screw sensor into bore.
3.
Tighten nut (3) with torque wrench to specified tightening torque.
Name
Sensor
4.
If necessary, roll up sensor cable to correct length and secure with cable clamps.
5.
Screw on electronics box (1) at the eyelets.
6.
Connect connector (2) and engage it.
208 | Wiring (General) for Engine/Gearbox/Unit | MS150104/02E 2016-11
Size
Type
M20 x 1.5 Tightening torque
Part No.
F30452769
F30027340
X00067260
(→ Spare Parts Catalog)
(→ Spare Parts Catalog)
(→ Spare Parts Catalog)
Lubricant
Value/Standard
40 Nm +4 Nm
Qty.
1
1
1