1.4540.041 – TecJet Internal Fault
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for operation.
1.4540.042 – Keyswitch State
Red alarm. Initiated by TecJet.
Cause
Secondary alarm following
emergency engine stop.
1.4540.043 – Parameter Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for operation.
1.4540.044 – Parameter Version Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for operation.
1.4540.045 – Main EEP Read Fail
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for operation.
1.4540.046 – Main EEP Write Fail
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for operation.
1.4540.047 – Reading Parameters
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for operation.
Corrective action
1. Restart TecJet.
2. Replace TecJet.
Corrective action
1. Rectify cause of alarm.
2. Check cabling (→ Page 201).
Corrective action
1. Restart TecJet.
2. Replace TecJet.
Corrective action
1. Restart TecJet.
2. Replace TecJet.
Corrective action
1. Restart TecJet.
2. Replace TecJet.
Corrective action
1. Restart TecJet.
2. Replace TecJet.
Corrective action
1. Restart TecJet.
2. Replace TecJet.
MS150104/02E 2016-11 | Troubleshooting | 115