Table of Contents

Advertisement

Quick Links

®
Aladin TEC 3H
User manual

Advertisement

Table of Contents
loading

Summary of Contents for Uwatec Aladin TEC 3H

  • Page 1 ® Aladin TEC 3H User manual...
  • Page 2: Safety Considerations

    • If Aladin TEC 3H fails at any time during the dive, the dive must be terminated, and appropriate surfacing procedures (including a slow ascent and a 3 to 5 minute safety stop at 5m /15ft) should be initiated immediately.
  • Page 3: Flying After Diving

    After a reset of the remaining saturation do not dive for at least 48 hours. Altitude and diving • Do not dive at altitudes higher than 4000m (13000ft). • After a dive do not rise to altitudes that Aladin TEC 3H prohibits via the flashing altitude range number (see page 30). Flying after diving •...
  • Page 4: Introduction

    - equipped with Scubapro innovative technology - while diving. We thank you for choosing Aladin TEC 3H and we hope you will enjoy safe dives in the future! Further information on Scubapro and Scubapro products can be found on our web page at www.scubapro.com.
  • Page 5: Quick Reference

    Quick reference Quick reference Time of day / Date Do not fly icon Decompression depth Setting icon Desaturation time (DESAT) No-dive warning Service icon Duration of no-dive warning Duration of surface interval Dive time / No-fly time / Current depth SOS duration Altitude sections Repetitive dive number...
  • Page 6 Operating scheme Display switched off Gas d O Gas 2 O Gas 1 O Logbook Diveplanner Page 1 Surface Oxygen Oxygen Oxygen DEPTH DIVE TIME interval Dive time – concentration concentration concentration – – – depth No-stop dive Battery Date of No-stop time performance the dive...
  • Page 7: Table Of Contents

    Introduction to Scubapro LogTRAK ................10 Switching on the display ....................14 How to navigate Aladin TEC 3H at the surface .............. 14 Checking the desaturation time ..................15 Checking the surface interval ..................15 2.10 Displaying the date ..................
  • Page 8 List of chapters 4.5.3 Desaturation time, No-fly time and No-dive warning ..........29 Diving in mountain lakes ....................30 4.6.1 Altitude ranges ....................30 4.6.2 Decompression dives in mountain lakes ..............31 Gauge Mode .........................32 Diving with microbubble (MB) levels ................34 4.8.1 Comparison of dives with MB level L0 and MB level L5 ......
  • Page 9: System And Operation

    The data can be transmitted with an infrared interface (IrDA) and LogTRAK software to a Windows personal computer. ® LogTRAK software CD is included with the Aladin TEC 3H package. Infrared interfaces are available in PC. LogTRAK Aladin TEC 3H...
  • Page 10: Water Contacts

    On submerging in water the water contacts switch on Aladin TEC 3H automatically. WARNING If you have chosen the option "Water contacts off" ("set 1", ->70), Aladin TEC 3H will turn on with a delay of up to 1 minute into the dive. This will affect functioning of the computer.
  • Page 11 System and operation Download dive profiles From LogTRAK, by selecting Dive -> Download Dives you can transfer the Aladin TEC 3H Logbook to your PC or Mac. There are three main views each showing a specific part of your dive logs: Profile shows the graphical data of the dive.
  • Page 12 Change warnings/settings of the Aladin TEC 3H and reading the computer information By selecting Extras -> Read Dive Computer settings you can enable/disable warnings that cannot be enabled or disabled by using the menus on the Aladin TEC 3H unit.
  • Page 13 System and operation Read the chapter Warnings and alarms about the possible selections that you can modify on your Aladin TEC 3H. You may also change the shown units between metric/imperial. Select Extras -> Options -> measurement units:...
  • Page 14: Switching On The Display

    If there is a remaining saturation from the last dive or from a change of altitude, Time of day display Aladin TEC 3H also displays the "do not fly" time, the "do not fly" icon, the current altitude range and the prohibited altitude range (->30).
  • Page 15: Checking The Desaturation Time

    2x or 3 x (depending on whether there is desaturation time left). Aladin TEC 3H displays the estimated remaining battery performance for 5 seconds as a bar graph. If the bar graph shows 3 segments the battery warning appears ->16 and Battery condition / the battery has to be replaced ->76.
  • Page 16: Active Backlight

    Diving not possible, dive planner and settings are disabled Aladin TEC 3H marks dives started with 3 or less segments in the logbook with the battery symbol. Logbook information is not lost even when the battery is removed for a long time.
  • Page 17: Switching Off The Display

    System and operation / SOS 2.13 Switching off the display From the time of day display you can switch off Aladin TEC 3H by pushing On the surface Aladin TEC 3H switches off automatically after 3 minutes without operation. 2.14 Alarm clock The alarm clock goes off only at the surface.
  • Page 18: Diving With Aladin Tec 3H

    DIVING WITH ALADIN TEC 3H 4.1 Terminology / Symbols The information on the display of Aladin TEC 3H varies depending on the kind of dive and the dive phase. For information about diving with microbubble (MB) levels see page 34. Specific features “Diving...
  • Page 19: Display During Decompression Phase

    Diving with Aladin TEC 3H 4.1.2 Display during decompression phase Decompression stop Total ascent time to surface (7min) All required decompression Time stops must be observed. Deepest decompression DEPTH DIVE TIME stop depth 2min DECO Decompression STOP CNS O stop duration...
  • Page 20: Nitrox Information (O Information)

    Maximum Operating Depth (MOD). When you enter the settings for the gas mixture, Aladin TEC 3H will display the max limit setting and the corresponding MOD. Aladin TEC 3H warns you audibly and visually once the depth is reached at which the ppO reaches the maximum allowed value ->26.
  • Page 21: Attention Messages And Alarms

    If you turn off the sound you will have no audible warnings. Without audible warnings you could inadvertently get into potentially hazardous situations which could result in death or serious injury. WARNING Serious injury or death may result from failing to immediately respond to alarms given by Aladin TEC 3H. 4.2.1 Attention messages 4.2.2 Alarms...
  • Page 22: Preparation For The Dive

    Functions during the dive 4.3 Preparation for the dive You have to check the settings of Aladin TEC 3H especially before the first dive. All settings can be checked and changed directly at Aladin TEC 3H or via LogTRAK. 4.3.1 Setting the gas mixture and ppO...
  • Page 23: Preparation For The Dive And Function Check

    WARNING If you have chosen the option "Water contacts off" ("set 1" or LogTRAK), Aladin TEC 3H will turn on with a delay of up to 1 minute into the dive. This will affect functioning of the computer. Make sure that the computer is on before starting the dive.
  • Page 24: Current Depth / O

    Functions during the dive If a dive lasts longer than 199 minutes the dive time display starts again at 0 minutes. 4.4.4 Current depth / O % mix Current depth is given in 10cm increments in metric setting and 1ft increments in imperial setting.
  • Page 25: Ascent Rate

    • In case of an improper ascent Aladin TEC 3H may require a decompression stop even within the no-stop phase because of the danger of microbubble formation. •...
  • Page 26: Partial Pressure Of Oxygen (Ppo Max) / Maximum Operating Depth (Mod)

    The MOD is a function of ppO max and the mixture used. If during the dive the MOD is reached or exceeded Aladin TEC 3H sends an audible attention message and the MOD is displayed (flashing) in the lower left corner.
  • Page 27: Nitrogen Loading Bar Graph

    Functions during the dive • Aladin TEC 3H will display CNS O % values exceeding 199 % with 199 %. • Aladin TEC 3H displays CNS O % values above 50%. 4.4.10 Nitrogen loading bar graph The nitrogen loading bar gives a graphical representation of how close to decompression you are. As you absorb nitrogen during the dive, more and more segments of the bar will light up.
  • Page 28: Safety Stop Timer

    Ascent time greater than 99 minutes is displayed as " – – ". Total ascent time WARNING On all dives with Aladin TEC 3H, make a safety stop for at least three minutes at a depth of 5m (15ft). 4.4.12 Safety stop timer...
  • Page 29: Functions At The Surface

    4.5.2 Residual nitrogen bar graph The segments in the residual nitrogen bar graph will gradually turn off as Aladin TEC 3H follows the offgassing of your tissues during your surface interval. There is a 1:1 equivalence in the meaning of the segments between diving and surface.
  • Page 30: Diving In Mountain Lakes

    Surface interval If Aladin TEC 3H detects a situation of increased risk (due to the potential of microbubble accumulation from previous dives or a CNS O level above 40%), the no-dive symbol No-dive will appear on the display.
  • Page 31: Decompression Dives In Mountain Lakes

    Altitude ranges 3280ft 13.12psi 6.2 Prohibited altitude WARNING Flying while Aladin TEC 3H displays "do not fly" may lead to serious Ascent to altitude range injury or death from decompression sickness. 3 and 4 prohibited. Max allowed altitude: 2650 m (8694ft).
  • Page 32: Gauge Mode

    (If Aladin TEC 3H shows “ – – – “ the gauge mode cannot be switched “on” or “off”. Aladin TEC 3H shows “ – – – “ for 48 hours after a dive in gauge mode and as long as there is remaining desaturation after a dive in computer mode.)
  • Page 33 Minutes Seconds After diving in gauge mode Aladin TEC 3H shows the remaining time span during which it cannot be used in computer mode. Once the waiting period is over, the gauge mode can be switched off manually. The no-fly time after diving in gauge mode is 48 hours.
  • Page 34: Diving With Microbubble (Mb) Levels

    (level stop) sooner than a diver using level L0. If a diver ignores a required level stop, Aladin TEC 3H will cascade to a lower MB level and the dive can not be completed with the initially chosen MB level. E.g. if a diver sets level L4 on Aladin TEC 3H prior to the dive and during the dive ignores the recommended stops Aladin TEC 3H will automatically adjust the setting to level L3 or lower.
  • Page 35: Comparison Of Dives With Mb Level L0 And Mb Level L5

    4.8.1 Comparison of dives with MB level L0 and MB level L5 When two Aladin TEC 3H are used simultaneously, one unit is set for example to MB level L5, the other to L0, the no-stop time will be shortened and level stops will be required before the diver has the obligation of a decompression stop.
  • Page 36: Display During Level Stop Phase

    > (Tank pressure)… 4.8.3 Preparation for a dive with MB levels Setting the MB level To change the MB level Aladin TEC 3H must be in user mode (time of day display). 1. Push until the symbol for MB levels until appears.
  • Page 37: Functions During The Dive With Mb Levels

    DEPTH DIVE TIME MB no-stop time While diving with MB levels L1 to L5 Aladin TEC 3H will display the NO STOP MB no-stop time instead of the ordinary no-stop time. Within the MB no-stop time no level stops are required.
  • Page 38: Total Time Of Ascent

    The warning “MB level reduced” is activated if the diver ascends more than 1.5m (5ft) above the required level stop. Aladin TEC 3H reduces the MB level, an attention beep* goes off and the new MB level is shown in the lower left corner.
  • Page 39: Decompression Obligation

    Diving with microbubble (MB) levels Decompression obligation Aladin TEC 3H calculates and displays level stops to reduce microbubble formation, but it also calculates the diver’s decompression data. WARNING Avoid decompression dives when diving with MB levels. How to avoid decompression stops:...
  • Page 40: Complete A Dive With Mb Levels

    Repetitive dives and MB levels: If during a dive a level stop is being ignored and the diver starts another descent shortly afterwards, Aladin TEC 3H might immediately request level stops. To complete the dive with the initially set MB level all level stops must be observed.
  • Page 41: Pdis (Profile Dependent Intermediate Stop)

    Spending 2 or 15 minutes at 30m/100ft would result in the same deep stop of 15m/50ft. With PDIS, as the name suggests, Aladin TEC 3H interprets your dive profile and suggests an intermediate stop that is a function of your nitrogen uptake so far. The PDI stop will therefore change through the course of the dive to reflect the continuosly changing situation in your body.
  • Page 42: How Does Pdis Work

    PDIS (Profile Dependent Intermediate Stop) 4.9.2 How does PDIS work? The mathematical decompression model in Aladin TEC 3H, called ZH-L8 ADT MB, tracks your decompression status by dividing your body into 8 so-called compartments and mathematically following the uptake and release of nitrogen in each with the appropriate laws of physics. The various compartments simulate parts of your body such as central nervous system, muscles, bones, skin and so on.
  • Page 43: Diving With Pdis

    NO to indicate the fact that you have not performed the PDI stop. If Aladin TEC 3H is displaying a decompression obligation when you reach the PDIS depth during an ascent, all rules apply the same way, but the 2-minute countdown runs in the background and is not displayed on the screen.
  • Page 44 PDIS (Profile Dependent Intermediate Stop) NOTE: Aladin TEC 3H issues no warnings relating to a missed PDI stop. When diving with MB levels, PDIS follows the same rules as described above. MB levels, however, introduce stops earlier and deeper than the L0 base algorithm. As such, the PDIS display may be delayed and for certain dives it may not be displayed at all.
  • Page 45: Diving With 2 Or 3 Gas Mixtures

    Aladin TEC 3H enables you to use up to 3 different Nitrox mixtures during the same dive. Tank 1 contains the bottom mix (gas 1), tank 2 the travel mix and tank d contains the deco mix (gas d).
  • Page 46 3. If you set gas 2 and gas d to “– – O %”, Aladin TEC 3H will compute the dive considering gas 1 only. Aladin TEC 3H will only accept gas switch depths (MOD gas 2 / gas d) as input where the maximum partial pressure of oxygen (ppO max), as pre-set manually (->22 point 5) or by means of LogTRAK, are...
  • Page 47 (MOD gas 2 /gas d). If a diver ignores a required change or changes the mixture belatedly, Aladin TEC 3H will readjust the decompression calculation accordingly. In case of an ignored switch the dive computer will then base its calculations on...
  • Page 48 (no switch to gas 2 / deco gas). This is the calculation that Aladin TEC 3H would switch to in case, having reached the switch depth, the diver did not confirm the switch. The decompression information and the O % blink.
  • Page 49 Diving with 2 or 3 gas mixtures Gas 1 active, MB level L0 DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DEPTH DIVE TIME DIVE TIME DECO DECO DECO DECO STOP STOP STOP STOP CNS O CNS O Decompression Tank...
  • Page 50 If a diver fails to confirm the change of gas mixture or interrupts the switching procedure by pressing , Aladin TEC 3H displays “GAS 1” / “GAS 2”, the MOD and the oxygen fraction for 5 seconds. Aladin TEC 3H continues to calculate with gas 1 / gas 2 only and adapts the decompression calculation...
  • Page 51 If after the decompression calculation has readjusted itself to reflect the failed switch the diver goes again below the switch depth (MOD of gas 2 / gas d), Aladin TEC 3H will revert to the decompression calculation that considers gas 2 / gas d also, since upon ascending again the diver will have a renewed opportunity to perform the switch once the switch depth is reached.
  • Page 52: Ccr Diving

    4.11.1 Preparation for the CCR dive You have to check the settings of Aladin TEC 3H especially before the first dive. All settings can be checked and changed directly at Aladin TEC 3H or via LogTRAK. Switching the CCR option on and off In order to enable CCR diving you must turn on the CCR option in the SET 1 menu ->68.
  • Page 53 Change the ppO (+) and (–) 5. By pushing you can change the ppO in the range of 0.3 to 0.95bar. Aladin TEC 3H will now display the corresponding MOD for the new ppO 6. Confirm your ppO settings with 7. Push until the SP2 menu appears.
  • Page 54 • If CCR is enabled at the SET1 in surface mode and up to a depth of 0.8m Aladin TEC 3H will display “CC” in the lower right corner of the display instead of a percentage value.
  • Page 55: Functions During A Ccr Dive

    (setpoint 1/2). If a diver ignores a required change or changes the SP1 / SP2 belatedly, Aladin TEC 3H will readjust the decompression calculation accordingly. In case of an ignored switch the dive computer will then base its calculations on the...
  • Page 56 SP2 not used (decompression information relative to SP1 only). This is the calculation that Aladin TEC 3H would switch to in case, having reached the switch depth, the diver did not confirm the switch. The decompression information and the O % blink.
  • Page 57 CCR Diving SP1 active, MB level L0 DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DIVE TIME DEPTH DIVE TIME DECO DECO DECO DECO STOP STOP STOP STOP CNS O CNS O Decompression Tank Temperature MOD SP1 Time pressure...
  • Page 58 When the switch depth is reached an audible warning goes off and MOD blinks as long as the current depth is below MOD. Below SP1 MOD, Aladin TEC 3H calculates according to SP1 ppO2 content; this may lead to long decompression requirement since nitrogen fraction increases above the diluent content.
  • Page 59 CCR Diving DEPTH DIVE TIME MOD SP2 Selected ppO SP2 x100 3. Press to confirm the switch. The text is shown for 5 seconds without blinking. DEPTH DIVE TIME Change to bottom setpoint confirmed To interrupt the switch process at any point, press 2x Changing form bottom SP2 to SP1 Time Switching range...
  • Page 60 CCR Diving Switch depth DEPTH DIVE TIME Switch from bottom SP2 to SP1 MOD SP1 Procedure: 1. Switch your CCR from SP2 to SP1 and start breathing. 2. Confirm the change by pressing within 30 seconds. “SP1” and the oxygen fraction of the Diluent is displayed for 5 seconds without blinking.
  • Page 61 If a diver fails to confirm the change of setpoint or interrupts the switching procedure by pressing 2x , Aladin TEC 3H displays “SP2”, the MOD and the ppO2 for 5 seconds. Aladin TEC 3H continues to calculate with rebreather injecting 100% Oxygen (maximum reached ppO2 depends on ambient pressure) and adapts the decompression calculation accordingly.
  • Page 62: Dive Planner

    (SP1 and SP2). 5.1 Planning a no-stop dive To select the dive planner Aladin TEC 3H must be in user mode (time of day display). Push until the symbol for the dive planner PLn appears. (The dive planner cannot be selected in gauge mode.)
  • Page 63: Planning A Decompression Dive

    If the no-dive warning and its duration has been displayed, Aladin TEC 3H proposes this time – rounded up to the next 15 minutes – as surface interval.
  • Page 64: Leaving The Dive Planner

    . Aladin TEC 3H calculates the decompression information for this set bottom time. If an MB level (L1-5) is selected, Aladin TEC 3H calculates the level stop data. CNS O2% values higher than 199% will be displayed as 199 %.
  • Page 65: Logbook

    6.1 Survey A dive is entered in the logbook if the dive time is longer than 2 minutes. Aladin TEC 3H records the profiles of about 15 hours of diving. This information can be transferred to a PC with the standard infrared interface (IrDA) and the Windows software LogTRAK.
  • Page 66 Logbook Page 2 Altitude range (if >0) Repetitive dive number Starting time CNS value at the end of the dive Minimum temperature Push to get more information about the dive. Page 3 Gas used gives the consumed gas amount on that dive. Page 4 SOS if applicable If a dive is started within adaptation time (after a change of altitude),...
  • Page 67 Logbook Statistic information From the time of day display you can get the following statistic information over all dives. Push Deepest dive DEPTH DIVE TIME Longest dive Cumulative bottom time Leaving the logbook By pushing once or twice you can exit the Number of dives logbook.
  • Page 68: Settings

    Settings SETTINGS 7.1 Menu "set 1" With menu "set 1" or LogTRAK you can configure the following items (dive functions): Setting Range Default Page • CCR mode on / off • Depth alarm 5-100m / 15-330ft 40m/130ft • Dive time alarm 5-195 min 60min •...
  • Page 69 Settings Setting the dive time alarm 1. Confirm that you wish to change the dive time alarm by pushing 2. Change the value in increments of 5 minutes by pushing 3. Switch between 'on' or 'off' by pressing 4. Confirm the setting with Setting the safety stop counter time 1.
  • Page 70 2. Switch between "on" or "off" by pressing 3. Confirm the setting with Switching the water contacts on and off On submerging in water the water contacts switch on Aladin TEC 3H automatically. WARNING If you chose the option "Water contacts off", Aladin TEC 3H will turn on with a delay of up to 1 minute into the dive.
  • Page 71: Menu "Set 2

    / high • Sound on / off • Show Aladin TEC 3H electronic ID Starting from the time of day display push until "set 2" appears. Confirm that you wish to enter into the menu of "set 2" by pushing...
  • Page 72 Settings Setting the alarm clock time The alarm clock goes off only at the surface. "Sound" must be turned "on" in "set 2". 1. Confirm that you wish to set the alarm time by pushing The hours start to flash. 2.
  • Page 73 Setting the "sound" to "off" applies also to surface functions (mountain alarm, wake-up alarm, change of altitude range). Showing the hardware electronic ID of Aladin TEC 3H This number is needed when reporting problems or for other maintenance related issues.
  • Page 74: Appendix

    Check Aladin TEC 3H high pressure connection and hose condition periodically and service them at least every 2 years. Rinse Aladin TEC 3H carefully with fresh water after each use and to have the batteries changed when needed ->76. To avoid possible problems with your Aladin TEC 3H, the...
  • Page 75: Connecting The High Pressure Hose

    On the surface: if service icon and error code "E3" appear, replace the battery ->76. All error codes other than E3: Aladin TEC 3H must not be used for any further dives. Take your dive computer to an authorized Scubapro dealer.
  • Page 76: Replacing The Battery (Battery Kit Includes Battery And Teflon Coated O-Ring)

    To replace the battery you need a coin or a universal tool and a clean cloth. WARNING • A leaking battery cap may lead to the destruction of Aladin TEC 3H by water seeping in or cause Aladin TEC 3H to switch off without prior notice. •...
  • Page 77: Warranty

    Insert the new battery, with "+" pointing outwards, into the battery compartment. After battery replacement Aladin TEC 3H will perform an automatic test (8s) and gives a short beep when the test is done. WARNING 10.
  • Page 78 Appendix Your dive instrument is manufactured with high-quality components that can be recycled and reused. Nevertheless these components, if not properly managed in accordance with the regulations on waste electrical and electronic equipment, are likely to cause harm to the environment and/or to human health.
  • Page 79: Index

    _________________ 20, 21, 26 partial pressure, ppO max ________ 20, 22, 26, 69 toxicity ________________________ 20, 21, 26 Operating Aladin TEC 3H ______________ 4, 5, 9 PC, transfer to PC (logbook) ____________ 9, 12 PDIS ___________________________________41 , see O...

Table of Contents