140
(0.98, 9.8)
120
(0.8, 8)
100
(0.7, 7)
80
(0.55, 5.5)
60
(0.41, 4.1)
40
(0.28, 2.8)
20
(0.14, 1.4)
0
0
30
(114)
To find Fluid Outlet Pressure (psi/MPa/bar) at a
specific fluid flow (gpm/lpm) and operating air
pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.
Performance Charts
Aluminum Husky 3275 Fluid Outlet Pressure
Test Conditions:
Pump tested in water with inlet submerged.
A
B
C
D
E
60
90
(227)
(341)
FLUID FLOW––gpm (lpm)
Fluid Pressure Curves
A at 120 psi (0.8 MPa, 8 bar) air pressure
B at 100 psi (0.7 MPa, 7 bar) air pressure
C at 70 psi (0.48 MPa, 4.8 bar) air pressure
D at 40 psi (0.28 MPa, 2.8 bar) air pressure
E at 20 psi (0.14 MPa, 1.4 bar) air pressure
120
150
180
(454)
(568)
(681)
To calculate Pressure Head in feet at a specific fluid outlet
pressure (psi):
pressure head, feet = (psi * 2.31) / specific gravity of fluid
To calculate Pressure Head in meters at a specific fluid outlet
pressure (MPa):
pressure head, meters = (MPa * 102) / specific gravity of fluid
To calculate Pressure Head in meters at a specific fluid outlet
pressure (bar):
pressure head, meters = (bar * 10.2) / specific gravity of fluid
210
240
270
(795)
(908)
(1022)
308639