Thermistors - Manitowoc indigo series Technician's Handbook

Air/water/remote condenser ice machine
Hide thumbs Also See for indigo series:
Table of Contents

Advertisement

THERMISTORS

FUNCTION
Thermistor resistance values change with temperature.
The value supplied to the control board is used to identify
temperature at the thermistor location.
SPECIFICATIONS
Temperature of
Thermistor
°C
-30° - -20°
-20° - -10°
-10° - 0°
0° - 10°
10° - 20°
20° - 30°
30° - 40°
40° - 50°
50° - 60°
60° - 70°
70° - 80°
80° - 90°
90° - 100°
100° - 110°
110° - 120°
120° - 130°
130° - 140°
140° - 150°
150° - 160°
160° - 170°
170° - 180°
180° - 190°
190° - 200°
188
°F
-22° - -4°
-4° - 14°
14° - 32°
32° - 50°
50° - 68°
68° - 86°
86° - 104°
104° - 122°
122° - 140°
140° - 158°
158° - 176°
176° - 194°
194° - 212°
212° -230°
230° - 248°
248° - 266°
266° - 284°
284° - 302°
302° - 320°
320° - 338°
338° - 356°
356° - 374°
374° - 392°
Part Number STH025 11/16
Resistance
K Ohms (x 1000)
820.85 - 466.35
466.35 - 269.05
269.05 - 160.70
160.70 - 98.930
98.930 - 62.015
62.015 - 39.695
39.695 - 25.070
25.070 - 17.481
17.481 - 11.860
11.860 - 8.1900
8.1900 - 5.7530
5.7530 - 4.1015
4.1015 - 2.9735
2.9735 - 2.1885
2.1885 - 1.6290
1.6290 - 1.2245
1.2245 - 0.9319
0.9319 - 0.7183
0.7183 - 0.5624
0.5624 - 0.4448
0.4448 - 0.3530
0.3530 - 0.2831
0.2831 - 0.2273