Manitowoc indigo series Technician's Handbook page 264

Air/water/remote condenser ice machine
Hide thumbs Also See for indigo series:
Table of Contents

Advertisement

I1800W
Self-Contained Water-Cooled Model
Characteristics vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Around Ice
Machine °F/°C
70/21
80/27
90/32
100/38
110/43
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Around Ice
Machine °F/°C
70/21
80/27
90/32
100/38
110/43
1 Based on average ice slab weight of 13.20 - 14.80 lb.
OPERATING PRESSURES
Air Temp
Around Ice
Machine
°F/°C
50/10
70/21
80/27
90/32
100/38
110/43
1 Suction pressure drops gradually throughout the freeze cycle
2 Water regulating valve set to maintain 230 psig
3 Condenser Water Usage = 181 gal/100 lb ice @ 90°/70°F
264
Water Temperature °F/°C
50/10
8.8-10.0
8.9-10.2
9.0-10.3
9.1-10.4
9.2-10.5
Freeze Cycle
Discharge
Pressure
Pressure
PSIG
230-240
220-280
230-240
240-270
240-280
240-280
Freeze Time
70/21
9.8-11.2
10.0-11.3
10.1-11.5
10.3-11.7
10.5-11.9
Water Temperature °F/°C
50/10
70/21
1850
1820
1810
1780
1790
Suction
Discharge
Pressure
PSIG
45-25
145-165
40-26
160-180
45-25
145-165
50-25
150-190
55-25
155-190
55-25
155-190
Part Number STH025 11/16
Harvest
Time
90/32
11.0-12.5
11.1-12.6
11.2-12.7
0.75-2.0
11.3-12.8
11.3-12.9
90/32
1680
1520
1660
1510
1640
1500
1610
1490
1590
1480
Harvest Cycle
Suction
Pressure
PSIG
PSIG
65-80
70-90
65-80
70-90
70-90
70-90
1
1
1

Advertisement

Table of Contents
loading

Table of Contents