FUNCTION
Thermistor resistance values change with
temperature. The value supplied to the control board is
used to identify temperature at the thermistor location.

SPECIFICATIONS

:
Temperature of Thermistor
°C
-30° - -20°
-20° - -10°
-10° - 0°
0° - 10°
10° - 20°
20° - 30°
30° - 40°
40° - 50°
50° - 60°
60° - 70°
70° - 80°
80° - 90°
90° - 100°
100° - 110°
110° - 120°
120° - 130°
130° - 140°
140° - 150°
150° - 160°
160° - 170°
170° - 180°
180° - 190°
190° - 200°
Part Number STH038 5/12
°F
-22° - -4°
-4° - 14°
14° - 32°
32° - 50°
50° - 68°
68° - 86°
86° - 104°
104° - 122°
122° - 140°
140° - 158°
158° - 176°
176° - 194°
194° - 212°
212° -230°
230° - 248°
248° - 266°
266° - 284°
284° - 302°
302° - 320°
320° - 338°
338° - 356°
356° - 374°
374° - 392°
Resistance
K Ohms (x 1000)
820.85 - 466.35
466.35 - 269.05
269.05 - 160.70
160.70 - 98.930
98.930 - 62.015
62.015 - 39.695
39.695 - 25.070
25.070 - 17.481
17.481 - 11.860
11.860 - 8.1900
8.1900 - 5.7530
5.7530 - 4.1015
4.1015 - 2.9735
2.9735 - 2.1885
2.1885 - 1.6290
1.6290 - 1.2245
1.2245 - 0.9319
0.9319 - 0.7183
0.7183 - 0.5624
0.5624 - 0.4448
0.4448 - 0.3530
0.3530 - 0.2831
0.2831 - 0.2273
155