Haier HLTD500ACW Service Manual page 20

Top load electric dryer
Hide thumbs Also See for HLTD500ACW:
Table of Contents

Advertisement

SERVICE MANUL
Model No.HLTD500ACW
2.Insert a UL listed strain relief into the mounting bracket hole. Position the strain relief
so that one tab is pointing up and one tab is pointing down. Tighten the strain relief
screws just enough to hold the two halves together.
A
Tab
B
Strain Relief
3.Insert a power cord into the strain relief. Take care to ensure that the wire insulation
of the power cord is inside the strain relief.
4.Connect power cord wires following Part A for a 4-wire power cord connection or Part
B for a 3-wire power cord connection.
4-wire (recommended) if your home has a 4-wire receptacle (NEMA
14-30 type SRDT or ST):
3-wire (if 4-wire is not available) if your home has a 3-wire receptacle
(NEMA 10-30 type SRDT):
CAUTION:
5. Tighten strain relief screws.
6. Be sure that none of the wires are touching the dryer drum inside the dryer
cabinet.
7. Reinstall the terminal block cover.
PART A - 4-WIRE POWER CORD
A A
A
Ground Screw (Green)
B
Terminal Block Screw
C
Neutral-Ground Jumper Wire (White)
D
Power Cord Ground Wire (Green)
A
B
A 4-wire connection is required for mobile homes and where
local codes do not permit the use of 3-wire connections.
A
B
C
D
E
F
G
E
Power Cord Neutral Wire (White)
F
Power Cord Line Wires (One Red;
One Black
Power Cord
G
- 19 -
Issue
Rev.

Advertisement

Table of Contents
loading

Table of Contents