Changing from under air intake to back air intake
Remove the suction board cover attached to the back, and screw it to the bottom of unit.
Installation location of receiving unit
The sensor of indoor unit with wireless remote controller can receive a signal by distance within approx. 8 m.
Based upon it, determine a place where the remote controller is operated and the installation place.
• Operate the remote controller, confirm that the indoor unit receives a signal surely, and then install it.
• Keep 1 m or more from the devices such as television, stereo.
(Disturbance of image or noise may generate.)
• To prevent a malfunction, select a place where is not influenced by a fluorescent light or direct sunlight.
Remove the top and bottom fan case screws,
and fasten the fan case with the suction board.
– 51 –