Rating Plate - CLIMAVENETA accurate ax Installation - User - Maintenance Manual

Precision air-conditioners
Hide thumbs Also See for accurate ax:
Table of Contents

Advertisement

RATING PLATE

The air-conditioner rating plate is positioned on a panel inside the
unit, and provides the following information:
- Model and serial number of the unit;
- Power supply (voltage, phases and frequency);
- Power input of the unit and the individual components;
- Current input of the unit and the individual components: OA
(Operating current), FLA (Full load current) and LRA (Locked
rotor current);
- Settings of the pressure switches in the refrigerant circuit (HP
and LP);
- Type of refrigerant (R410A);
- Charge or pre-charge in each refrigerant circuit (AW versions
only)
TECHNICAL DATA
ACCURATE - AX Air-cooled direct expansion unit
Model
Frame
No. of circuits / no. of compressors
Refrigerant
Rated air flow-rate
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
FANS
No. of std. EC radial fans
No. of HP EC radial fans
Sound pressure level (5)
REFRIGERANT CONNECTIONS
Refrigerant connections (ODS Ø)
HUMIDIFIER
Capacity
ELECTRIC HEATERS
Steps
Heating capacity
DIMENSIONS
Length
Depth
Height
OUTDOOR UNIT COMBINATIONS
BRE remote condenser
BREC remote condenser
1 - Inside air 24°C-50%, Cond. temperature 45°C - ESP 20 Pa
5 - Average sound pressure level, at a distance of 2 m, for units in a free field on a reflecting surface.
The average sound pressure level is calculated based on the sound power level measured in accordance with ISO 3744.
ACCURATE AX - AW - AD - AT - AF
5
7
10
F1
1/1
1/1
1/1
mc/h
1800
2500 2500 4900 4900 6500 8000 8000 13500 10500 13500 13500 19000 19000 19000 25000 25000
V/Ph/Hz 230/1/50
kW
4,96
7,2
9,6
16,3
kW
4,95
7,2
9,2
16,3
1,00
1,00
0,96
1,00
kW
1,22
1,69
2,20
3,64
kW
0,16
0,40
0,40
0,84
kW
0,13
0,27
0,27
0,53
V/Ph/Hz
n.a
kW
n.a.
7,73 10,03 17,06 19,95 23,95 27,79 31,93 42,9 34,94 47,49 50,07
kW
n.a.
7,73
9,41 17,06 18,54 23,89 27,79 29,96 42,9 34,94 47,49 48,9
n.a.
1,00
0,94
1,00
kW
n.a.
1,87
2,37
3,99
kW
n.a.
0,40
0,40
0,84
kW
n.a.
0,27
0,27
0,53
V/Ph/Hz
n.a
kW
n.a.
n.a.
n.a.
17,06 19,95 24,11 27,93 32,05 43,06 34,94 47,81 50,36 58,26 68,64 77,11 91,45 96,67
kW
n.a.
n.a.
n.a.
17,06 18,54 23,98 27,93 30,02 43,06 34,94 47,76 49,03 58,26 68,64 71,73 91,45 92,46
n.a.
n.a.
n.a.
1,00
kW
n.a.
n.a.
n.a.
3,99
kW
n.a.
n.a.
n.a.
0,84
kW
n.a.
n.a.
n.a.
0,53
V/Ph/Hz
n.a
kW
n.a.
7,85 10,23 17,15 19,95 24,25 27,92 32,2 43,06 35,18 48,1 50,43 58,16 68,92 77,11 91,05 96,97
kW
n.a.
7,81
9,5
17,15 18,54 24,05 27,92 30,08 43,06 35,18 47,91 49,06 58,16 68,92 71,93 91,05 92,46
n.a.
0,99
0,93
1,00
kW
n.a.
1,87
2,40
3,97
kW
n.a.
0,40
0,40
0,80
kW
n.a.
0,27
0,27
0,53
1
1
1
1
1
1
dB(A)
43
50
50
IN - LIQ
12
12
12
OUT-GAS
12
12
12
kg/h
3
3
3
3
3
3
kW
4
4
4
mm
600
mm
500
mm
1980
007m
014m 014m 022m 027m 027m 044m 044m 051m 054b 054b 065b 065b 076b 100b 100b 116b
M1A
M1D M1D M2B M2C M2D M3C M3D M3D M3D_B M2F_B M3G_B M3G_B M3F_B M4E_B M4F_B M4F_B
15
18
20
26
29
39
F2
F3
1/1
1/1
1/1
1/1
1/1
1/1
R410A
400/3N/50
19,1
23,3
28,9
31,8
41
18,2
23,3
28,8
29,9
41
0,95
1,00
1,00
0,94
1,00
4,31
4,93
6,00
6,93
7,86
0,84
1,35
1,80
1,80
3,20
0,53
0,89
1,69
1,69
3,51
460/3/60
0,93
1,00
1,00
0,94
1,00
4,41
5,18
5,91
7,21
8,33
0,84
1,35
1,80
1,80
3,20
0,53
0,89
1,69
1,69
3,51
380/3/60
0,93
0,99
1,00
0,94
1,00
4,41
5,28
5,93
7,35
8,53
0,84
1,35
1,80
1,80
3,20
0,53
0,89
1,69
1,69
3,51
230/3/60
0,93
0,99
1,00
0,93
1,00
4,41
5,25
5,99
7,36
8,53
0,80
1,20
1,97
1,97
3,50
0,53
1,13
1,85
1,85
3,80
2
2
1
1
1
2
2
2
1
1
1
2
53
53
56
60
60
64
12
12
16
16
16
16
12
18
18
22
22
22
5
5
5
5
5
5
3
3
3
3
3
3
8
8
9
9
9
15
1000
1000
500
790
1980
1980
Mod.151 rev.03
Type
Modèle
Modello
Modelo
Model
Typ
Item
Article
Articolo
Artículo
Einzelteil
Produktkodning
Serial number
Matricule unité
Matricola unità
Matricula unidad
Seriennummer
Serienummer
Manufact. year
Année construction
Anno di costruz.
Año de costrucción
Baujahr
Tillverkningsår
Operating weight
Poids en fonction.
Peso in funzionam.
Peso en funcionam
Betriebsgewicht
Driftsvikt
Refrigerant
Gaz réfrigérant
Gas refrigerante
Gas refrigerante
Kältemittel
Köldmedium
Refr. charge
Q.té gaz réfrig.
Carica refrigerante
Carga refrigerante
Füllgewicht
Köldmediefyllning
ELECTRICAL SUPPLY
Auxiliary
Main
F.L.I.
kW
F.L.A.
A
L.R.A.
A
MAXIMUM ALLOWABLE PRESSURE (PS)
Gas circuit:
HP=
MPa
LP=
MPa
Water circuit:
MPa
Maximum transport and storage temperature:
° C
Manual n° :
Wiring Diagrams:
rev.
36061 BASSANO DEL GRAPPA (VI)
ITALIA - via SARSON, 57/C
Tel.+39 0424 509500 Fax+39 0424 509509
e-mail: info@climaveneta.it
30
40
50
55
60
70
F4
F5
2/2
2/2
2/2
2/2
2/2
2/2
33,4
46,2
52,3
60,3
68,1
73,2
33,4
46,2
49,9
60,3
68,1
70,1
1,00
1,00
0,95
1,00
1,00
0,96
7,26
9,85 12,02 12,02 13,86 15,69 17,70 21,34
1,30
3,20
3,20
4,50
4,50
4,50
2,09
3,51
3,51
5,11
5,11
5,11
58
68,36 76,75 91,93 97,27
58
68,36 71,58 91,71 92,58
1,00
1,00
0,98
1,00
1,00
0,93
7,98 10,36 11,78 11,86 14,47 16,62 18,84 21,16
1,30
3,20
3,20
4,50
4,50
4,50
2,09
3,51
3,51
5,11
5,11
5,11
1,00
1,00
0,97
1,00
1,00
0,93
7,98 10,55 11,84 11,90 14,72 17,00 19,81 22,07
1,30
3,20
3,20
4,50
4,50
4,50
2,09
3,51
3,51
5,11
5,11
5,11
1,00
1,00
0,97
1,00
1,00
0,93
7,93 10,50 11,95 12,02 14,73 17,00 19,33 22,07
2,10
3,50
3,50
4,90
4,90
4,90
3,35
3,80
3,80
5,55
5,55
5,55
2
2
2
3
3
2
2
2
3
3
59
64
64
67
67
67
12
16
16
16
16
16
18
18
22
22
22
22
5
5
5
8
8
3
3
3
3
3
15
15
15
18
18
18
1550
2100
790
790
1980
1980
80
90
F6
2/2
2/2
87,8
95,4
87,8
91,8
1,00
0,96
6,10
6,10
6,72
6,72
1,00
0,95
6,10
6,10
6,72
6,72
1,00
0,96
6,10
6,10
6,72
6,72
1,00
0,95
7,60
7,60
7,10
7,10
3
3
3
3
4
4
67
67
18
18
22
22
8
8
8
3
3
3
18
18
2650
790
1980
EN
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accurate adAccurate afAccurate atAccurate aw

Table of Contents