ACCURATE - AW Water-cooled direct expansion unit
Model
Frame
No. of circuits / no. of compressors
Refrigerant
Rated air flow-rate
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
FANS
No. of std. EC radial fans
No. of HP EC radial fans
Sound pressure level (5)
PLATE CONDENSER
Type
Number
Water content
Water flow-rate (1)
Pessure drop Dp (1)
CONNECTIONS
Condenser water connections *
HUMIDIFIER
Capacity
ELECTRIC HEATERS
Steps
Heating capacity
DIMENSIONS
Length
Depth
Height
OUTDOOR UNIT COMBINATIONS
BDC Dry Cooler
1 - air 24°C-50%, water 30-35°C - ESP 20 Pa
5 - Average sound pressure level, at a distance of 2 m, for units in a free field on a reflecting surface.
The average sound pressure level is calculated based on the sound power level measured in accordance with ISO 3744.
*WARNING,THE DIAMETERS OF THE CONNECTION LINES BETWEEN THE INDOOR UNIT AND DRY COOLER MUST BE SIZED
BY THE INSTALLER BASED ON THE INSTRUCTIONS SHOWN IN THE PARAGRAPH ON WATER CONNECTIONS
10
EN
5
7
10
F1
1/1
1/1
1/1
mc/h
1800
2500 2500 4900 4900 6500 8000 8000 13500 10500 13500 13500 19000 19000 19000 25000 25000
V/Ph/Hz 230/1/50
kW
5,26
7,5
9,8
16,9
kW
5,08
7,5
9,3
16,9
0,97
1,00
0,95
1,00
kW
1,1
1,47
1,91
3,26
kW
0,16
0,40
0,40
0,84
kW
0,13
0,27
0,27
0,53
V/Ph/Hz
n.a
kW
n.a.
8,03 10,29 17,65 20,54 25,19 28,13 33,1 44,83 36,28 49,83 52,43 60,3 71,01 80,67 97,19 103,69
kW
n.a.
7,74
9,5
17,36 18,61 24,14 27,75 29,94 43,36 35,6 49,09 49,06 60,3 69,21 72,44 93,98 95,24
n.a.
0,96
0,92
0,98
kW
n.a.
1,66
2,08
3,56
kW
n.a.
0,40
0,40
0,84
kW
n.a.
0,27
0,27
0,53
V/Ph/Hz
n.a
kW
n.a.
n.a.
n.a.
17,65 20,54 25,33 28,26 33,2 44,92 36,28 50,08 52,71 60,54 71,23 80,89 96,57 103,23
kW
n.a.
n.a.
n.a.
17,36 18,61 24,2 2782 29,98 44,43 35,6 49,23 49,17 60,54 69,33 72,53 93,73 95,04
n.a.
n.a.
n.a.
0,98
kW
n.a.
n.a.
n.a.
3,56
kW
n.a.
n.a.
n.a.
0,84
kW
n.a.
n.a.
n.a.
0,53
V/Ph/Hz
n.a
kW
n.a.
8,12 10,34 17,77 20,54 25,46 28,24 33,34 44,92 36,56 50,32 52,78 60,38 71,52 80,89 95,97 103,23
kW
n.a.
7,78
9,52 17,41 18,61 24,25 27,81 30,05 44,43 35,75 49,36 49,2 60,38 69,48 72,53 93,48 95,04
n.a.
0,96
0,92
0,98
kW
n.a.
1,67
2,10
3,55
kW
n.a.
0,40
0,40
0,80
kW
n.a.
0,27
0,27
0,53
1
1
1
1
1
1
dB(A)
43
50
50
1
1
1
l
0,8
0,8
0,8
l/h
1094
1560 2030 3490 4110 4980 5990 6800 8640 3570x2 4940x2 5655x2 6335x2 7205x2 7875x2 18430 20510
kPa
3
8
14,00 5,13
IN
3/4" M
3/4" M 3/4" M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 2" M
OUT
3/4" M
3/4" M 3/4" M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 2" M
kg/h
3
3
3
3
3
3
kW
4
4
4
mm
600
mm
500
mm
1980
008m
013m 013m 030m 030m 030m 039m 039m 052m 039m 052m 062m 078m 078m 092m 103m 123m
15
18
20
26
29
39
F2
F3
1/1
1/1
1/1
1/1
1/1
1/1
R410A
400/3N/50
19,8
24,5
29,2
33,0
43,0
18,3
23,8
28,3
29,9
43,0
0,92
0,97
0,97
0,91
1,00
3,93
4,28
5,38
6,24
6,91
0,84
1,35
1,80
1,80
3,20
0,53
0,89
1,69
1,69
3,51
460/3/60
0,91
0,96
0,99
0,90
0,97
4,11
4,53
5,24
6,52
7,36
0,84
1,35
1,80
1,80
3,20
0,53
0,89
1,69
1,69
3,51
380/3/60
0,91
0,96 98,44 0,90
0,99
4,11
4,63
5,32
6,65
7,60
0,84
1,35
1,80
1,80
3,20
0,53
0,89
1,69
1,69
3,51
230/3/60
0,91
0,95
0,98
0,90
0,99
4,11
4,63
5,37
6,66
7,60
0,80
1,20
1,97
1,97
3,50
0,53
1,13
1,85
1,85
3,80
2
2
1
1
1
2
2
2
1
1
1
2
53
53
56
60
60
64
AISI316 plate heat exchanger
1
1
1
1
1
1
3,9
3,9
2,5
2,5
3
3,8
7,08
23
31
27
30
5
5
5
5
5
5
3
3
3
3
3
3
8
8
9
9
9
15
1000
1000
500
790
1980
1980
30
40
50
55
60
F4
F5
2/2
2/2
2/2
2/2
2/2
34,8
48,5
54,5
62,6
70,8
34,8
48,4
49,9
62,6
69,1
1,00
1,00
0,92
1,00
0,98
6,42
8,53 10,76 10,77 12,38 13,54 15,90 19,15
1,30
3,20
3,20
4,50
4,50
2,09
3,51
3,51
5,11
5,11
0,98
0,99
0,94
1,00
0,97
7,49
9,03 10,38 10,56 12,98 14,39 16,27 18,59
1,30
3,20
3,20
4,50
4,50
2,09
3,51
3,51
5,11
5,11
0,98
0,98
0,93
1,00
0,97
7,03
9,21 10,55 10,71 13,21 14,93 17,30 19,53
1,30
3,20
3,20
4,50
4,50
2,09
3,51
3,51
5,11
5,11
0,98
0,98
0,93
1,00
0,97
7,01
9,23 10,67 10,82 13,23 14,93 16,82 19,53
2,10
3,50
3,50
4,90
4,90
3,35
3,80
3,80
5,55
5,55
2
2
2
3
3
2
2
2
3
3
59
64
64
67
67
2
2
2
2
2
2x1,6 2x2,5 2x2,5 2x2,5 2x3 2x3,8
24
21
30
34
30
5
5
5
8
8
3
3
3
3
3
15
15
15
18
18
1550
2100
790
790
1980
1980
ACCURATE AX - AW - AD - AT - AF
70
80
90
F6
2/2
2/2
2/2
77,4
90,6
99,3
71,1
90,0
92,8
0,92
0,99
0,93
4,50
6,10
6,10
5,11
6,72
6,72
0,90
0,97
0,92
4,50
6,10
6,10
5,11
6,72
6,72
0,90
0,97
0,92
4,50
6,10
6,10
5,11
6,72
6,72
0,90
0,97
0,92
4,90
7,60
7,60
5,55
7,10
7,10
3
3
3
3
4
4
67
67
67
2
1
1
8,5
8,532
26
31
39
2" M
2" M
8
8
8
3
3
3
18
18
18
2650
790
1980

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accurate adAccurate afAccurate atAccurate aw

Table of Contents