ACCURATE - AT Water-cooled direct expansion unit
Model
Frame
No. of circuits / no. of compressors
Refrigerant
Rated air flow-rate
Power supply
CAPACITY DELIVERED (DX)
Gross total capacity (1)
Gross sensible capacity (1)
SHR (1)
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Water flow-rate (1)
Pessure drop Dp (1)
Power supply
CAPACITY DELIVERED (DX)
Gross total capacity (1)
Gross sensible capacity (1)
SHR
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Water flow-rate (1)
Pessure drop Dp (1)
Power supply
CAPACITY DELIVERED (DX)
Gross total capacity (1)
Gross sensible capacity (1)
SHR
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
Power supply
CAPACITY DELIVERED (DX)
Gross total capacity (1)
Gross sensible capacity (1)
SHR
Compressor power consumption
Power cons. with std. EC radial fans
Power cons. with HP EC radial fans
CAPACITY DELIVERED (CW)
Gross total capacity (6)
Gross sensible capacity (6)
SHR
Water flow-rate (6)
Total unit pressure drop (6)
Water content
FANS
No. of std. EC radial fans
No. of HP EC radial fans
Sound pressure (5)
PLATE CONDENSER
Type
Number
Water content
CONNECTIONS
Condenser water connections *
Water connections *
HUMIDIFIER
Capacity
ELECTRIC HEATERS
Steps
Heating capacity
DIMENSIONS
Length
Depth
Height
OUTDOOR UNIT COMBINATIONS
BDC Dry Cooler
1 - air 24°C-50%, water 30-35°C - ESP 20 Pa
5 - Average sound pressure level, at a distance of 2 m, for units in a free field on a reflecting surface.
The average sound pressure level is calculated based on the sound power level measured in accordance with ISO 3744.
6 - air 24°C-50% water 7-12°C - ESP 20 Pa
*WARNING,THE DIAMETERS OF THE CONNECTION LINES BETWEEN THE INDOOR UNIT AND DRY COOLER MUST BE SIZED
BY THE INSTALLER BASED ON THE INSTRUCTIONS SHOWN IN THE PARAGRAPH ON WATER CONNECTIONS
ACCURATE AX - AW - AD - AT - AF
20
26
29
F3
1/1
1/1
1/1
mc/h
6000
7500
8000
V/Ph/Hz
kW
24,9
30,6
32,3
kW
22,8
28,3
30,0
0,92
0,92
0,93
kW
4,30
5,40
6,11
kW
1,35
1,80
1,80
kW
0,89
1,60
1,80
l/h
4900
6330
7002
kPa
24
32
28
V/Ph/Hz
kW
25,6
29,4
32,3
kW
23,1
27,7
30,0
0,90
0,95
0,93
kW
4,66
5,29
6,39
kW
1,35
1,80
1,80
kW
0,89
1,69
1,69
l/h
5080
6240
6650
kPa
24
32
28
V/Ph/Hz
kW
25,8
29,5
32,4
kW
23,2
27,8
30,1
0,90
0,94
0,93
kW
4,8
5,4
6,5
kW
1,35
1,80
1,80
kW
0,89
1,69
1,69
V/Ph/Hz
kW
25,9
29,4
32,5
kW
23,3
27,8
30,1
0,90
0,94
0,93
kW
4,76
5,43
6,54
kW
1,20
1,97
1,97
kW
0,99
1,76
2,01
kW
23,8
28,1
29,5
kW
21,8
26,4
27,6
0,92
0,94
0,94
l/h
3890
4590
4590
kPa
26
35
35
l
9,3
9,3
9,3
1
1
1
1
1
1
dB(A)
56
60
60
1
1
1
l
0,8
0,8
0,8
IN
1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M
OUT
1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M 1" 1/4 M
IN
1"1/2 F
1"1/2 F
1"1/2 F
OUT
1" F
1" F
1" F
kg/h
5
5
5
3
3
3
kW
9
9
9
mm
1000
mm
790
mm
1980
030m
039m
039m
39
30
40
50
F4
1/1
2/2
2/2
2/2
R410A
13000
10000
13000
13500
400/3N/50
47,3
38,1
50,0
54,5
46,9
36,7
47,9
50,7
0,99
0,96
0,96
0,93
6,94
6,44
8,61
10,55
3,20
1,30
3,20
3,20
3,40
2,09
3,40
3,65
8430
3690 x 2 4905 x 2 5977x2 7180x2 8066x2
31
27
21
32
460/3/60
48,9
39,8
51,4
52,5
48,1
37,6
48,7
49,9
0,98
0,94
0,95
0,95
8,49
8,14
9,09
10,17
3,20
1,30
3,20
3,20
3,51
2,09
3,51
3,51
9580
3865 x 2 5075 x 2 5625 x 2 7155 x 2 7795 x 2 18640
31
27
21
32
380/3/60
49,0
39,8
51,7
52,7
48,1
37,6
48,8
50,0
0,98
0,94
0,95
0,95
8,8
7,1
9,3
10,4
3,20
1,30
3,20
3,20
3,51
2,09
3,51
3,51
230/3/60
49,0
40,4
51,9
52,8
48,1
37,9
49,0
50,0
0,98
0,94
0,94
0,95
8,76
7,06
9,30
10,47
3,50
2,10
3,50
3,50
3,66
2,14
3,66
3,95
50,0
41,0
50,0
51,4
46,3
37,0
46,3
47,5
0,93
0,90
0,93
0,92
8170
6710
8170
8170
46
30
46
46
14,1
14,1
14,1
14,1
2
2
2
2
2
2
2
2
64
59
64
64
AISI316 plate heat exchanger
1
1
1
1
3,9
3,9
2,5
2,5
1"1/2 F
1"1/2 F
1"1/2 F
1"1/2 F
1" F
1" F
1" F
1" F
5
5
5
5
3
3
3
3
15
15
15
15
1550
790
1980
052m
039m
052m
062m
60
70
80
90
F5
F6
2/2
2/2
2/2
2/2
18000
19000
24000
24000
70,3
76,6
91,8
101,9
66,8
71,1
88,2
92,2
0,95
0,93
0,96
0,90
12,28
13,30
16,03
19,33
4,50
4,50
6,10
6,10
4,50
5,20
6,72
6,72
18120
20830
30
28
33
41
70,5
79,8
95,9
103,4
66,9
72,5
88,0
90,6
0,95
0,91
0,92
0,88
12,89
14,15
16,67
18,85
4,50
4,50
6,10
6,10
5,11
5,11
6,72
6,72
21000
30
28
33
41
70,7
80,1
95,3
103,0
67,0
72,5
87,7
90,4
0,95
0,91
0,92
0,88
13,1
14,7
17,7
19,8
4,50
4,50
6,10
6,10
5,11
5,11
6,72
6,72
71,0
80,1
95,9
103,0
67,1
72,5
88,0
90,4
0,95
0,91
0,92
0,88
13,14
14,65
16,67
19,81
4,90
4,90
7,60
7,60
4,86
5,63
7,10
7,10
65,0
67,6
91,0
91,0
62,2
64,5
85,0
85,0
0,96
0,95
0,93
0,93
10630
10630
14870
14870
26
26
53
53
19,2
19,2
24
24
3
3
3
3
3
3
4
4
67
67
67
67
1
1
2
2
3
3,8
2x1,6
2x2,5
2" M
2" M
2" M
2" M
2" F
2" F
2" F
2" F
1"1/2 F
1"1/2 F
1"1/2 F
1"1/2 F
8
8
8
8
3
3
3
3
18
18
18
18
2100
2650
790
790
1980
1980
078m
092m
103m
123m
EN
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accurate adAccurate afAccurate atAccurate aw

Table of Contents