POWER CONSUMPTION OF INDIVIDUAL COMPONENTS (COMPRESSOR)
Vers.
Frame
Mod.
1
05
1
07
1
10
1
07
1
10
2
15
2
18
3
20
3
26
3
29
4
39
4
30
4
40
4
50
5
55
5
60
5
70
6
80
6
90
Vers.
Frame
Mod.
1
05
1
07
1
07
1
10
2
15
2
18
3
20
3
26
3
29
4
39
4
30
4
40
4
50
5
55
5
60
5
70
6
80
6
90
Vers.
Frame
Mod.
1
05
1
07
1
07
1
10
2
15
2
18
3
20
3
26
3
29
4
39
4
30
4
40
4
50
5
55
5
60
5
70
6
80
6
90
Values for individual component
FLI = Maximum power consumption
FLA = Max current
LRA = Locked rotor current
ACCURATE AX - AW - AD - AT - AF
Unit power supply
V/ph/Hz
230/1/50
230/1/50
230/1/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
400/3N/50
Unit power supply
V/ph/Hz
/
/
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
460/3/60
Unit power supply
V/ph/Hz
/
/
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
380/3/60
R410A compressor
V/ph/Hz
Qty.
FLI (kW)
230/1/50
1
230/1/50
1
230/1/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
1
400/3N/50
2
400/3N/50
2
400/3N/50
2
400/3N/50
2
400/3N/50
2
400/3N/50
2
400/3N/50
2
400/3N/50
2
R410A compressor
V/ph/Hz
Qty.
FLI (kW)
/
/
/
/
460/3/60
1
460/3/60
1
460/3/60
1
460/3/60
1
460/3/60
1
460/3/60
1
460/3/60
1
460/3/60
1
460/3/60
2
460/3/60
2
460/3/60
2
460/3/60
2
460/3/60
2
460/3/60
2
460/3/60
2
460/3/60
2
R410A compressor
V/ph/Hz
Qty.
FLI (kW)
/
/
/
/
380/3/60
1
380/3/60
1
380/3/60
1
380/3/60
1
380/3/60
1
380/3/60
1
380/3/60
1
380/3/60
1
380/3/60
2
380/3/60
2
380/3/60
2
380/3/60
2
380/3/60
2
380/3/60
2
380/3/60
2
380/3/60
2
FLA (A)
1,98
8,95
2,9
13,4
3,83
18,1
2,9
4,9
3,7
6,5
5,9
11,8
7,3
15
8,3
15
10,1
21
11,7
22
13,4
25
5,9
11,8
8,3
15
10,1
21
10,1
21
11,7
22
13,4
25
14,6
31
17
34
FLA (A)
/
/
/
/
3,33
5,5
4,15
6
7,05
10
7,01
11,8
8,71
15
9,91
15
12,1
21
14,05
22
7,05
10
8,71
15
9,91
15
9,91
15
12,1
21
14,05
22
16,1
25
17,55
31
FLA (A)
/
/
/
/
3,33
13,4
4,15
17,8
7,05
11,5
7,01
14
8,63
15
9,6
18,1
12,05
23,8
14,1
27,9
7,05
11,5
8,63
15
9,6
18,1
9,6
18,1
12,05
23,8
14,1
27,9
15,9
31,6
17,55
33
EN
LRA (A)
36
61
98
32
46
64
75
101
111
118
118
64
101
111
111
118
118
140
174
LRA (A)
/
/
27
35
62
62
75
100
114
125
62
75
100
100
114
125
125
150
LRA (A)
/
/
64
79
65,6
83
73
94,3
140
145
65,6
73
94,3
94,3
140
145
145
139