4—Tau Digital Data Channel
4.1

Using the Digital Data Channel

Note
The following instructions assume that you have purchased the optional serial-to-parallel-out
(SIPO) accessory module with parallel data cable and Photon Replicator Board. If you are
using the Ethernet module, follow the instructions provided with that device. If you are using
custom cabling and/or interface electronics, contact FLIR Customer Support at (805) 964-
9797 if you need additional assistance.
Follow the steps in paragraph 3.1 "Operation of the Tau camera using the Photon development
kit" on page 3-1 for basic operation of the Tau camera. After verifying that the camera is
operating properly, disconnect power from the I/O Module.
Step 1
Connect the SIPO accessory module directly to the three-row DB-15 connector on the
Interface Module labeled DIGITAL DATA as shown below. A cable is NOT required.
I/O Module
To camera
To frame grabber board
Step 2
Connect the parallel data cable to the mating connector on the SIPO module. Connect
the other end to the frame-grabber board installed in your PC.
Note
The parallel data cable is specific to a particular frame grabber. Contact the manufacturer of
the frame grabber to make sure you have the correct cable.
Step 3
Follow instructions included with the frame grabber for selecting the camera
configuration file included with the SIPO module.
Step 4
Reapply power to the Interface Module. This will power-up both the Tau camera and
the SIPO module, and digital data will begin streaming.
Step 5
If desired, change the digital data mode using the FLIR Camera Controller software in
the Digital Video tab.
4-2
April 2009
Tau User's Manual
SIPO Module
TAU-0035-00-10, version 100