10 Operational Specifications
E_CLOCK
AB10..0
DB7..0
R_W
XCS
Figure 10-16: Synchronous Motorola-Mode, WRITE (AS = 1)
No.
31
E_Clock pulse width
Address setuptime (A10..0) to E_Clock ↑
33
Address holdtime after E_Clock ↓
37
E_Clock ↑ to Data valid
32
Data holdtime after E_Clock ↓
38
R_W setuptime to E_Clock ↑
35
R_W holdtime after E_Clock ↓
39
XCS setuptime to E_Clock ↑
36
XCS holdtime after E_Clock ↓
40
Data setuptime to E_Clock ↓
41
Data holdtime after E_Clock ↓
42
Figure 10-17: Timing, Synchronous Motorola Mode
90
33
valid
35
36
Parameter
Revision 1.03
31
41
data valid
VDD = 3.3 V
MIN
MAX
136.7
136.7
10
5
103
4
16
10
5
0
0
10
10
VPC3+C User Manual
Copyright © profichip GmbH 2004-2006
37
42
39
40
VDD = 5 V
Unit
MIN
MAX
ns
10
ns
5
ns
97
ns
4
12
ns
10
ns
5
ns
0
ns
0
ns
10
ns
10
ns