According to IEC 61158, Static Diagnosis should only be used during
s
tart-up.
Status coding for the diagnosis buffers is stored in the Diag_Buffer_SM
control parameter. The user can read this cell with th
b
oth buffers: User, VPC3+, or VPC3+_Send_Mode.
Address
bit 7-4
bit 3-2
bit 1-0
Figure 6-9: Diagnosis Buffer Assignment
The New_Diag_Cmd is also a read access to a defined control parameter
indicating which Diagnosis-Buffer belongs to the user after the exchange or
whether both buffers ar
D
iag_Buf1, Diag_Buf2).
Address
Figure 6-10: Coding of New_Diag_Cmd
VPC3+C User Manual
Copyright © profichip GmbH 2004-2006
7
6
0CH
0
0
Diag_Buffer_SM, Address 0CH:
Don't care: Read as '0'
f2: Assignment of Diagnosis Buffer 2
Diag_Bu
00 = Nil
01 = User
10 = VPC3+
11 = VPC3_Send_Mode
f1: Assignment of Diagnosis Buffer 1
Diag_Bu
00 = Nil
01 = User
10 = VPC3+
11 = VPC3_Send_Mode
7
6
0DH
0
0
Revision 1.03
PROFIBUS DP Interface 6
Bit Position
5
4
3
2
0
0
Diag_Buf2
e currently assigned to the VPC3+C (No_Buffer,
Bit Position
5
4
3
2
0
0
0
0
e possible codings for
Designation
1
0
Diag_Buf1
Diag_Buffer_SM
Designation
1
0
New_Diag_
⇓
⇓
Buffer_Cmd
0
0
No_Buffer
0
1
Diag_Buf1
1
0
Diag_Buf2
45