10mm0
min.5mm
:
~
I
:
;~-:."'-
..
~
I
I
I
I
I
I
I
I
I
I
I
en
~
o
WALL MOUNTING PLATE
FLUE OPENING
CAUTION: Ensure there are no pipes, elec­
tric cables, damp proof courses or other
hazards before drilling.
SAFETY:
All relevant safety precautions must
be
uflder­
taken. Protective clothing, footwear, gloves and
safety goggles must
be
wom as appropriate.
FIXING THE POSITION OF THE WALL
MOUNTING PLATE:
• The diagram opposite shows the relative
positions of the flue and the fIXing of the wall
mounting plate, the mounting plate and
pre­
plumbing manifold.
I>
Place the wall mounting plate against the
wall in the desired position.
I>
Mark 3 fixing points through the holes (A, B,
C) in the wall mounting plate.
I>
Drill the 3 holes for wall mounting plate, wall
hanging bracket and pre-plumbing manifold.
.. Secure wall mounting plate with hanging
bracket with 3 screws (supplied with the
boiler). Do not fully fasten the lower 2
screws.
.. Use the horizontal slots in the wall mounting
plate to level the hanging bracket, mark the
4th hole and drill.
I>
Fi)( and secure the hanging bracket with
C
both screws.
FLUE OUTLET
.. Follow the diagram opposite to mark the
centre of the flue for rear outlet (1, & 2) or
for side outlet (2
&
3).
**
Note: increase this height by 52 mm for
every 1000 mm of horizontal length that the
flue outlet is away from the boiler.
I>
For the 60/100 mm
0
flue make a 125 mm
diameter hole through the wall using a core
drill or similar.
For flues using an optional weather collar,
fitted from inside the building make a
150 mm
0
hole.
.. Clear away any debris.
FIXING THE PRE-PLUMBING MANIFOLD:
.. Mount the pre-plumbing manifold on the 2
lower screws and secure the screws.
o
INSTALLATION
&
SERVICING INSTRUCTIONS FOR WORCESTER BOSCH GREENSTAR 25C0iI3OC0il37CDil42
co,
~ORCESTER
WALL MOUNTING PLATE
67'20 613 700. (2006il11)
Bosch GrouP
FLUE OPENING

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 30cdi gcGreenstar 37cdi gcGreenstar 42cdi gc

Table of Contents