Worcester GREENSTAR 25CDi GC Instruction Manual page 20

Wall hung rsf gas-fired condensing combination boiler
Hide thumbs Also See for GREENSTAR 25CDi GC:
Table of Contents

Advertisement

STANDARD FLUE HORIZONTAL
14-•..•__•.....••._..•......;
I
0100
MAX 686mm Ax1
MIN 250 mm Ax
l '
0125
MAX 1070 mm Ax 1
MIN 250 mm Ax
l'
*
Requires cutting
MAXIMUM FLUE HORIZONTAL
0100 . 2600 mm
Ax1+Bx2
0125·12500 mm
A xl
+
B x
12
MAXIMUM FLUE VERTICAL START + 1 BEND
F~ Q'
.
""'W
A
1 - 1
B
@
C
0100·2600 mm
Ax1+Cxl+8x3
+
Fx
1
0125· 12500 mm
A x 1 + C x 1 + B x 13
+
Fx
1
MAXIMUM FLUE HORIZONTAL + 1 BEND
Do
'···'··1 liP A
C=====:::3"
B
o
C
0100· 600 mm
Ax1+8x1+Cx1
0125·10500 mm
Axl + Bxll +Cxl
MAXIMUM FLUE VERTICAL
START + 2 BENDS
F
E1
IG~WilP
A
B
1-,' .....
. ,::.
cO
0100· N/A
0125 . 10500 mm
A
x
1 + C x 2 + B x 12
+
Fx
1
MAXIMUM FLUE VERTICAL
START + 3 BENDS
F
~" ,·'~13,fP
B
c" . ' " "'. ,.,.:.
>.
C
0100· N/A
0125 8500 mm
Axl +Cx3
+Bx11+Fxl
MAXIMUM FLUE VERTICAL
WITH 2 X 45° BENDS
E
,
.
..
,
B
D
0100 - 2900 mm
(including terminal)
8x3+ Dx2 + Ex1
0125 - 14000 mm
(including terminal)
B x 14 + D x 2 + Ex 1
VERTICAL FLUE WITH
2 X 90° BENDS
E
t1
8
..
C
0
0100 - N/A
0125 - 12000 mm
(including terminal)
Bx13+ Cx2 +Exl
6
720
611 927-08.10
FLUE OPTIONS 42CDi
• The diagrams (opposite) show the compo ­
nents used and the maximum flue length for
each configuration of 100 mm and
125 mm 0 flues.
• Shaded flue components indicate the stan­
dard 100 mm 0 horizontal flue.
• Only straight flue sections can be reduced
in length and cut.
• The flue terminal end can be
fitted
from the
inside or outside of the building.
• Fixing kits are supplied with the flue exten·
sion kits.
• Horizontal 125 mm 0 and Vertical 100 mm
and 125 mm 0 flue kits are available with
separate instructions. Contact your supplier
or Worcester Bosch.
A
D
@fT'Ii?P
V
B
F
Jd.
A - Standard horizontal flue (100 mm 0 shown)
B
Straight flue extension
C
Flue bend, 90°
D· Flue bends, 45°
E· Vertical terminal (vertical adaptor supplied
with terminal)
F - Vertical adaptor (used with horizontal
terminal)
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Horizontal 60/100 mm 0: 2600 mm
Horizontal 80/125 mm 0: 12500 mm
Vertical 60/100 mm 0: 4900 mm
Vertical 80/125 mm 0: 16000 mm
Then reduce the total straight flue length for
each extra flue bend (excluding the turret) by:
2000 mm for 90°
1000 mm for 45°
Rue extension total lengths:
Horizontal
&
Vertical 60/100 mm 0: 960 mm
Horizontal & Vertical 80/125 mm 0: 1000 mm
Flue terminal total lengths:
Horizontal 60/100 mm 0: 800 mm
Horizontal 80/125 mm 0: 1200 mm
Vertical 60/100 mm 0: 1140 mm
Vertical 80/125 mm 0: 1365 mm
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER BOSCH GREENSTAR 25CDV3OCDiiSTCDi142 CDi
~ORCESTER
FLUE OPTIONS
42CDi
6720613700a (2006111)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 30cdi gcGreenstar 37cdi gcGreenstar 42cdi gc

Table of Contents