12.7. Remove Fuser Unit
B1
(A)-a
Fuser Cover and Fuser Unit
(1) Remove the bottom plate.
(2) Remove the 2 leads for high voltage
and 1 connector for the sensor. (Fig-01)
(3) Remove the 3 screws (A)-a.
(4) Remove the Fuser Cover.
(5) Remove the 2 screws (G).
(6) Remove the Fuser Unit.
(G)
Fuser Cover
Fuser Unit
Bottom View
2 leads for high valtage
2 leads for high valtage
Bottom view
Lead/Thermistor
Fig-01
Fig-01