11.2.17. High Voltage Section
1. Main
All of the outputs
are abnormal.
Replace the unit.
Check the HVPS unit failure.
Check the voltage of
pin8 of HVPS unit.
Is +24V power
output?
YES
Check the SW1.
Is it normal?
YES
Check the value of
the resistor F1.
Is the value of
the resistor 0 ?
YES
Make sure each output.
If any trouble is found, refer to
the manual for each part.
CHG BIAS ,
TRA (+) BIAS
GRID
181
NO
Check the Main Board.
NO
Replace the SW1.
NO
Replace the F1.
DEV BIAS
UF-5500 / 4500
TRA (-) BIAS