Important Health and Safety Information for Installers and Service Engineers
4-7.3 Connections to Electrastream Pre-Piped
Health and Safety at Work Act 1974
Consumer Protection Act 1987
COSHH Regulations 1988
HEATING EXPANSION
The following information is given as a requirement of the
VESSEL 10L
above legislation.
Great care is taken by GAH (HEATING PRODUCTS) LIMITED
to ensure that Electrastream systems are designed and
manufactured to meet general safety requirements when
properly used and installed as recommended in this manual.
It is the responsibility of Users and Engineers to ensure that
adequate protective clothing and glasses are worn when
UNVENTED CYLINDER
working with the Electrastream system.
SEALS AND INSULATION
SEALS AND INSULATION
SEALS AND INSULATION
SEALS AND INSULATION
SEALS AND INSULATION
Insulation and sealing materials are used in the construction
of the Electrastream cylinders. Units are sealed and when
4 4 4 4 4
used in the manner for which they are intended the insulating
CYLINDER TPR VALVE
and sealing materials do not present any known hazard.
However always observe the following recommendations:-
1.
Avoid inhalation of fibres or dust, wear face mask.
2.
Avoid eye contamination by fibres or dust - wear eye
THERMOSTATIC
MIXING VALVE FOR DHW
protection.
3.
As far as possible avoid any skin contact with Fibreglass
Insulation, Glass Rope, Mineral Wool, Insulation Pads and
COMBINATION VALVE
Ceramic Fibre.
HOT WATER PRV- 6 Bar
TUNDISH
CYLINDER DRAIN
COCK
In pursuance of a policy of constant development, GAH (HEATING PRODUCTS) LIMITED
reserve the right to change Electrastream parts or design without notice, therefore
TUNDISH DISCHARGE TO BE
certain details included in this manual may not be correct at the time of printing. Any
ARRANGED AND SIZED TO COMPLY
modification and improvements detailed in this manual does not commit GAH to update
WITH BUILDING REGULATIONS.
any system previously supplied.
Manual Part No. ...................MAN1019
Manual Ref ..........................ES02
Issue ...................................13
COLD MAINS IN
CONNECTION 22mm
Date .................................... 25/02/13
DOMESTIC HOT WATER OUT
CONNECTION 22mm
P P P P P atent application 01514800.2
atent application 01514800.2
atent application 01514800.2
atent application 01514800.2
atent application 01514800.2
HEATING FLOW 22mm CONNECTION
© © © © ©
2010 GAH (HEATING PRODUCTS) L
2010 GAH (HEATING PRODUCTS) L
2010 GAH (HEATING PRODUCTS) LTD.
2010 GAH (HEATING PRODUCTS) L
2010 GAH (HEATING PRODUCTS) L
Electrastr
Electrastr
Electrastr
Electrastr
Electrastream is a T
eam is a T
eam is a T
eam is a Trademark of GAH (HEATING PRODUCTS) L
eam is a T
IMPORTANT
rademark of GAH (HEATING PRODUCTS) LTD.
rademark of GAH (HEATING PRODUCTS) L
rademark of GAH (HEATING PRODUCTS) L
rademark of GAH (HEATING PRODUCTS) L
Plumbing must remain as supplied.
Do not add to or change any plumbing or connections.
HTS REF GAH ELECTRASTREAM 25/02/13
Manual by Harber Technical Services Tel/Fax 01263 515444
E-mail:info@harbertech.co.uk
46
2
CONSUMER UNIT
C/W DP ISOLATOR, RCD & MCB
TD.
TD.
TD.
TD.
TD.
TD.
TD.
TD.
www.harbertech.co.uk
Fig. 4-7c Electrastream Pre-Piped Connections
INST
INSTALLA
INST
HEAL
HEALTH & SAFETY
HEAL
INST
INST
HEAL
HEAL
OTHER MATERIALS
OTHER MATERIALS
OTHER MATERIALS
OTHER MATERIALS
OTHER MATERIALS
ELECTRASTREAM
SEALANTS, ADHESIVES AND PAINTS
CONTROL UNIT
Sealants, Adhesives and Paints are used in the construction of
the Electrastream components. When used in the manner for
which they are intended they do not present any known hazard.
ELECTRIC
ELECTRIC
ELECTRIC
ELECTRIC
ELECTRIC
The Cylinder Tri-Core Heater, Pump, Thermostats and Contactor
Box all have electrical supply of 230V (enough to endanger
life).
Always isolate before connection, adjustment, servicing and
repair.
When the Tri-Core Heater cover is removed high power live
electrical terminals are exposed.
ISOLATE THE TRI-CORE HEATER BEFORE REMOVING ITS
COVER.
Earth protection - Earth Continuity Conductors must be fitted
and must comply with IEE Wiring Regulations.
GAH (HEATING PRODUCTS) LIMITED will not accept
responsibility for any damage or personal injury caused
by not giving due consideration to the above safety
recommendations.
GAH (Heating Pr
GAH (Heating Pr
oducts) Ltd.
oducts) Ltd.
GAH (Heating Pr
GAH (Heating Products) Ltd.
GAH (Heating Pr
oducts) Ltd.
oducts) Ltd.
Building 846
Bentwaters Parks
Rendlesham
Woodbridge
HEATING RETURN CONNECTION 22mm
Suffolk IP12 2TW
T T T T T el: el: el: el: el:
01394 421160
01394 421160
01394 421160
01394 421160
01394 421160
SINGLE COIL SHOWN
Fax:
Fax:
Fax: 01394 421170
Fax:
Fax:
01394 421170
01394 421170
01394 421170
01394 421170
TWIN COIL 210 IS SIMILAR LAYOUT
email: mail@gah.co.uk
www.gah.co.uk
ALLATION
ALLA
ALLA
TH & SAFETY
TH & SAFETY
TH & SAFETY
TION
TION
TION
4
4
4
ALLA
TH & SAFETY
TION
4
4
HOT WATER
EXPANSION VESSEL 8L
FRAME
TEMPERATURE PROBE CABLE
& OVER TEMPERATURE CUT-
OUT CABLE
HEATING PR VALVE - 3 Bar
CYLINDER HEATING FLOW
CONNECTION
MOTORISED VALVE
HEATING CIRCULATING PUMP
& VALVES
CYLINDER TEMPERATURE SENSOR
IN BOX
OVER TEMPERATURE CUT-OUT
THERMOSTAT
HEATING SYSTEM FILLING LOOP
CONNECT ONLY FOR FILLING
TRI-CORE HEATER
3 qty x 3kW ELEMENTS
SUPPORT FRAME