GAH electrastream User And Installation Manual page 44

Single and twin coil models
Hide thumbs Also See for electrastream:
Table of Contents

Advertisement

Important Health and Safety Information for Installers and Service Engineers
4-7
Electrastream Connections
4-7.1 Connections to Electrastream - BEL130 and BEL150 Single Coil Cylinders
Health and Safety at Work Act 1974
Consumer Protection Act 1987
COSHH Regulations 1988
The following information is given as a requirement of the
above legislation.
Great care is taken by GAH (HEATING PRODUCTS) LIMITED
to ensure that Electrastream systems are designed and
DOMESTIC
HOT WATER 22mm
manufactured to meet general safety requirements when
properly used and installed as recommended in this manual.
 22mm LEVER VALVE
It is the responsibility of Users and Engineers to ensure that
adequate protective clothing and glasses are worn when
working with the Electrastream system.
TPRV connection not to be used
for any other purpose
SEALS AND INSULATION
SEALS AND INSULATION
SEALS AND INSULATION
SEALS AND INSULATION
SEALS AND INSULATION
Insulation and sealing materials are used in the construction
of the Electrastream cylinders. Units are sealed and when
4 4 4 4 4
used in the manner for which they are intended the insulating
and sealing materials do not present any known hazard.
However always observe the following recommendations:-
1.
Avoid inhalation of fibres or dust, wear face mask.
2.
Avoid eye contamination by fibres or dust - wear eye
Discharge to be arranged and
sized to comply with Building
protection.
Regulations G3.
3.
As far as possible avoid any skin contact with Fibreglass
Insulation, Glass Rope, Mineral Wool, Insulation Pads and
Ceramic Fibre.
 MOTORISED
VALVE
In pursuance of a policy of constant development, GAH (HEATING PRODUCTS) LIMITED
reserve the right to change Electrastream parts or design without notice, therefore
certain details included in this manual may not be correct at the time of printing. Any
modification and improvements detailed in this manual does not commit GAH to update
any system previously supplied.
Manual Part No. ...................MAN1019
Manual Ref ..........................ES02
Issue ...................................13
Date .................................... 25/02/13
P P P P P atent application 01514800.2
atent application 01514800.2
atent application 01514800.2
atent application 01514800.2
atent application 01514800.2
© © © © ©
2010 GAH (HEATING PRODUCTS) L
2010 GAH (HEATING PRODUCTS) L
2010 GAH (HEATING PRODUCTS) LTD.
2010 GAH (HEATING PRODUCTS) L
2010 GAH (HEATING PRODUCTS) L
Electrastream is a T
Electrastr
Electrastr
Electrastr
Electrastr
eam is a T
eam is a T
eam is a Trademark of GAH (HEATING PRODUCTS) L
eam is a T
rademark of GAH (HEATING PRODUCTS) LTD.
rademark of GAH (HEATING PRODUCTS) L
rademark of GAH (HEATING PRODUCTS) L
rademark of GAH (HEATING PRODUCTS) L
HTS REF GAH ELECTRASTREAM 25/02/13
 PARTS SUPPLIED
Manual by Harber Technical Services Tel/Fax 01263 515444
E-mail:info@harbertech.co.uk
44
2
 MI COUPLER x 22 x ¾”"
 TPR VALVE
 TUNDISH
CYLINDER
DRAIN COCK
Domestic Hot Water
22mm
Domestic Cold Water
22mm
Mains Supply
22mm
Tundish
-
TD.
TD.
TD.
TD.
Boiler Flow
22mm
TD.
TD.
TD.
TD.
Boiler Return
22mm
www.harbertech.co.uk
Fig. 4-7a Typical Electrastream Single Coil Cylinder Connections
OTHER MATERIALS
OTHER MATERIALS
OTHER MATERIALS
OTHER MATERIALS
OTHER MATERIALS
SEALANTS, ADHESIVES AND PAINTS
Sealants, Adhesives and Paints are used in the construction of
the Electrastream components. When used in the manner for
 UNVENTED CYLINDER
which they are intended they do not present any known hazard.
DOMESTIC
COLD WATER 22mm
ELECTRIC
ELECTRIC
ELECTRIC
ELECTRIC
ELECTRIC
The Cylinder Tri-Core Heater, Pump, Thermostats and Contactor
Box all have electrical supply of 230V (enough to endanger
DHW
life).
Always isolate before connection, adjustment, servicing and
 COMBINATION
repair.
VALVE
When the Tri-Core Heater cover is removed high power live
electrical terminals are exposed.
ISOLATE THE TRI-CORE HEATER BEFORE REMOVING ITS
COVER.
Earth protection - Earth Continuity Conductors must be fitted
PRV
and must comply with IEE Wiring Regulations.
No valves between cylinder and
combination valve
HEATING FLOW 22mm
 MI COUPLER x 22 x ¾”"
GAH (HEATING PRODUCTS) LIMITED will not accept
responsibility for any damage or personal injury caused
HEATING RETURN 22mm
by not giving due consideration to the above safety
 MI COUPLER x 22 x ¾”"
recommendations.
COLD INTO CYLINDER
 MI COUPLER x 22 x ¾”"
GAH (Heating Pr
GAH (Heating Pr
GAH (Heating Products) Ltd.
GAH (Heating Pr
GAH (Heating Pr
Building 846
22 x ¾”" M.I. Coupler - supplied
Bentwaters Parks
Fit 22mm Lever Valve - supplied
Rendlesham
Fit 22mm Lever Valve - supplied
Woodbridge
22mm x ¾”" BSP M.I. Coupler - supplied
Suffolk IP12 2TW
Discharge to be arranged and sized
to comply with Building Regulations G3.
T T T T T el: el: el: el: el:
01394 421160
01394 421160
01394 421160
01394 421160
01394 421160
22 x ¾”" M.I. Coupler - supplied
Fax:
Fax: 01394 421170
Fax:
Fax:
Fax:
01394 421170
01394 421170
01394 421170
01394 421170
22 x ¾”" M.I. Coupler - supplied
email: mail@gah.co.uk
www.gah.co.uk
INST
INSTALLA
INST
HEALTH & SAFETY
HEAL
HEAL
ALLA
ALLATION
ALLA
TH & SAFETY
TH & SAFETY
TH & SAFETY
TION
TION
TION
INST
INST
HEAL
HEAL
ALLA
TH & SAFETY
TION
 22mm LEVER VALVE
FROM MAINS
22mm
 DHW 8l EXPANSION VESSEL KIT
No valves between combination
valve and vessel
 TEMPERATURE SENSOR AND
OVER TEMPERATURE CUT-OUT
BOX
 TRI-CORE HEATER
oducts) Ltd.
oducts) Ltd.
oducts) Ltd.
oducts) Ltd.
4
4
4
4
4

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for GAH electrastream

Table of Contents