Helpful Hints - BEA IRIS Setup Manual

Presence detector
Hide thumbs Also See for IRIS:
Table of Contents

Advertisement

3.
Use the chart below as an aide for the manual programming procedure.
5
Manual Setup Of The Sensor – continued
REQUIRED: If the IR frequency has been manually changed, to prevent the sensors from being in permanent
5

Helpful Hints

High mounting height
(>10')
Rain/Snow
Setup
Access Code
Overlapping
IR-curtains
75.5159.09 20090115
PARAMETER NUMBER
(altered by the right button and
confirmed by RED LED)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
detection, momentarily depress the right program button to launch an assisted setup.
If the sensor is installed higher than 10' above the floor, make sure to use the narrow prism
(See Ch. 3).
If the sensor is exposed to rain or snow, use the URC (Universal Rain protection Cover)
Set the sensor to immunity level 2 or 3 to increase the immunity of the sensor.
Assisted Setup (~14sec)
Standard Setup (~4sec)
After adjusting the sensor for the first time, it is required to launch an 'Assisted Setup' (See Ch. 4).
If the IR sensor module 'sees' the door movement, move the curtains out of the door leaf.
The access code is recommended to set sensors close to each other with remote control. The access code can
be composed of 1 to 4 digits (factory values or no access code : 0 or 0000). No code is required to unlock during
the first minute after powering. To enter a lock code, simply press the Lock key, followed by a lock code. If lock code is
less than 4 digits, the lock key must be pressed a second time following the last digit of the code (See Pg. 5).
Overlapping IR-curtains from sensors installed side-by-side may cause disturbances due to crosstalk
(interferences). Select different frequencies on each sensor to avoid crosstalk (See Setting 'Installation
Configuration' on Pg.6).
Attention: avoid curtains that are overlapping by more than 12" (at 7' mounting height, using the wide prism).
PARAMETER
VALUES
(altered by the
left button and
confirmed by
GREEN LED)
Not Used
Relay hold time
Output configuration
Auto-learn
presence sensing
Not Used
Not Used
IR Immunity
Not Used
Not Used
IR curtain
Not Used
Height & Frequency
Not Used
Door control function
Not Used
Sensor checks the influence of the door leaves to the IR
curtains (performs a door open/door close cycle)
Sensor only learns its environment
DEFAULT
VALUE
-
-
-
-
1-4
4
0 = IRIS
0-9
9 = IRIS-I
-
-
-
-
1-3
2
-
-
-
-
1-2
2
-
-
1, 3
1
-
-
1-3
1
-
-
8/10