Needle Position Misalignment - ELNA 6125QC Service Manual

Table of Contents

Advertisement

Needle Position Misalignment

To check:
Select the pattern "
needle comes in the center needle drop position.
Slide the stitch width control from "0" to "6.5" and vice versa.
If the needle swings, correct it as follows:
Adjustment procedure:
1. Select the pattern "
2. Rotate the handwheel several turns until the needle comes in the center needle drop position.
3. Remove the front cover (See page 8.).
4. Loosen the setscrews (A) and (B). Slightly tighten the setscrew (A).
5. Adjust the position of the stitch width adjusting arm so that the needle does not swing when rocking the
stitch width adjusting lever. Tighten the setscrews (A) and (B).
6. Attach the front cover.
Mechanical Adjustment
" and set the stitch width control at "6.5". Rotate the handwheel several turns until the
" and set the stitch width control at "6.5".
Stitch width adjusting lever
Setscrew (A)
14
Stitch width
adjusting arm
Setscrew (B)

Advertisement

Table of Contents
loading

This manual is also suitable for:

6019qc

Table of Contents