Mechanical Adjustment

Presser Bar Height and Alignment

To check:
When the presser foot is raised, the clearance between the presser foot and the needle plate should be 6.0
mm.
When the presser foot is lowered, the edge of the foot and the feed dog windows on the needle plate should
be parallel.
Adjustment procedure:
1. Remove the face cover.
2. Raise the presser foot lifter (A), and loosen the screw (B) on the presser bar holder.
3. Adjust the distance between the presser foot (C) and the needle plate (D) to 6.0 mm (0.24").
4. Tighten the screw (B) securely.
5. Attach the face cover.
Note: When you tighten the screw (B), make sure that both sides of the presser foot are parallel to the feed
dog windows (E) on the needle plate.
Setscrew (4 x 8)
Presser foot lifter (A)
Presser Foot Alignment
Clearance between Foot and Needle Plate
Presser foot
Needle plate
Should be parrallel
6.0 mm
Feed dog
11