PDFMAILER.DE
TO CHECK:
1. Raise the presser foot lever (B).
2. The distance between the zigzag foot (A) and the needle plate (C) should be 6.0 mm (0.24''). If
the height is greater or less than 6 mm (0.24''), adjust as follows.
ADJUSTMENT:
1. Remove the face cover (see page 8).
2. Raise the presser foot lever (B) and loosen the screw (D) on the presser bar holder (E).
3. Adjust the distance between the zigzag foot (A) and the needle plate (C) to 6.0 mm (0.24'')
4. Tighten the screw (D) securely.
5. Attach the face cover.
Note: When you tighten the screw (D), make sure that both sides of the zigzag foot (A) are parallel.
PRESSER BAR HEIGHT AND ALIGNMENT
23