Copper Cabling Guidelines

Display a copy of your equipment map, including meanings of all abbreviations
at each equipment rack.
The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration,
which enables you to use standard straight-through twisted-pair cables to connect
to any other network device (PCs, servers, switches, routers, or hubs).
The connection requires an unshielded twisted-pair (UTP) or shielded twisted-pair
(STP) cable with RJ-45 connectors at both ends.

Table 8: Maximum Twisted-Pair Copper Cable Lengths

Cable Type
1000BASE-T
Category 5, 5e, or 6 100-ohm UTP or STP
100BASE-TX
Category 5 or better 100-ohm UTP or STP
10BASE-T
Category 3 or better 100-ohm UTP
To ensure proper operation when installing the switch into a network, make sure
that the current cables are suitable for 10BASE-T, 100BASE-TX, or 1000BASE-T
operation. Check the following criteria against the current installation of your
network:
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables
with RJ-45 connectors; Category 5, 5e or better cable for 1000BASE-T
connections, Category 5 or better for 100BASE-TX connections, and Category 3
or better for 10BASE-T connections..
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic
fields from data based network wiring
Safe connections with no damaged cables, connectors or shields
Maximum Cable Length
100 m (328 ft)
100 m (328 ft)
100 m (328 ft)